Artificial Intelligence-Assisted Biparametric MRI for Detecting Prostate Cancer—A Comparative Multireader Multicase Accuracy Study

<b>Objectives:</b> To evaluate the diagnostic accuracy of AI-assisted biparametric MRI (AI-bpMRI) in detecting prostate cancer (PCa) as a possible replacement for multiparametric MRI (mpMRI) depending on readers' experience. <b>Methods:</b> This fully crossed, multireader multicase, single-centre, consecutive study retrospectively included men with suspected PCa. Three radiologists with different levels of experience independently scored each participant's biparametric (bp) MRI, mpMRI, and AI-bpMRI according to the PI-RADS V2.1 classification. The AI-assisted image processing was based on a sequential deep learning network. Histopathological findings were used as a reference. The study evaluated the mean areas under the receiver operating characteristic curves (AUCs) using the jackknife method for covariance. AUCs were tested for non-inferiority of AI-bpMRI to mpMRI (non-inferiority margin: -0.05). <b>Results:</b> A total of 105 men (mean age 66 ± 7 years) were evaluated. AI-bpMRI was non-inferior to mpMRI in detecting both Gleason score (GS) ≥ 3 + 4 PCa (AUC difference: 0.03 [95% CI: -0.03, 0.08], <i>p</i> = 0.37) and GS ≥ 3 + 3 PCa (AUC difference: 0.04 [95% CI: -0.01, 0.09], <i>p</i> = 0.14) and was superior to bpMRI in detecting GS ≥ 3 + 3 PCa (AUC difference: 0.07 [95% CI: 0.02, 0.12], <i>p</i> = 0.004). The benefit of AI-bpMRI was greatest for the readers with low or medium experience (AUC difference in detecting GS ≥ 3 + 4 compared to mpMRI: 0.06 [95% CI: -0.03, 0.14], <i>p</i> = 0.19 and 0.06 [95% CI: -0.03, 0.14], <i>p</i> = 0.19, respectively). <b>Conclusions:</b> This study indicates that AI-bpMRI detects PCa with a diagnostic accuracy comparable to that of mpMRI.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-08-29
DOI
https://doi.org/10.3390/jcm14176111
Citations
2
Primary Topic
Prostate Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
3.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Artificial Intelligence-Assisted Biparametric MRI for Detecting Prostate Cancer—A Comparative Multireader Multicase Accuracy Study

Nikolaus Gaßler, Marc‐Oliver Grimm, Sabrina Reimers-Kipping, D. Nißler et al.
2 citations
Journal of Clinical Medicine
Prostate Cancer Diagnosis and Treatment
3.04
article

Artificial Intelligence-Assisted Biparametric MRI for Detecting Prostate Cancer—A Comparative Multireader Multicase Accuracy Study

Nikolaus Gaßler, Marc‐Oliver Grimm, Sabrina Reimers-Kipping, D. Nißler, Bernhard Theis, Tobias Franiel, Ulf Teichgräber, Maja Ingwersen, PR Franken, Frank Berger, Felix Niekrenz, Fabian Hielscher
article en
2 citations

Abstract

<b>Objectives:</b> To evaluate the diagnostic accuracy of AI-assisted biparametric MRI (AI-bpMRI) in detecting prostate cancer (PCa) as a possible replacement for multiparametric MRI (mpMRI) depending on readers' experience. <b>Methods:</b> This fully crossed, multireader multicase, single-centre, consecutive study retrospectively included men with suspected PCa. Three radiologists with different levels of experience independently scored each participant's biparametric (bp) MRI, mpMRI, and AI-bpMRI according to the PI-RADS V2.1 classification. The AI-assisted image processing was based on a sequential deep learning network. Histopathological findings were used as a reference. The study evaluated the mean areas under the receiver operating characteristic curves (AUCs) using the jackknife method for covariance. AUCs were tested for non-inferiority of AI-bpMRI to mpMRI (non-inferiority margin: -0.05). <b>Results:</b> A total of 105 men (mean age 66 ± 7 years) were evaluated. AI-bpMRI was non-inferior to mpMRI in detecting both Gleason score (GS) ≥ 3 + 4 PCa (AUC difference: 0.03 [95% CI: -0.03, 0.08], <i>p</i> = 0.37) and GS ≥ 3 + 3 PCa (AUC difference: 0.04 [95% CI: -0.01, 0.09], <i>p</i> = 0.14) and was superior to bpMRI in detecting GS ≥ 3 + 3 PCa (AUC difference: 0.07 [95% CI: 0.02, 0.12], <i>p</i> = 0.004). The benefit of AI-bpMRI was greatest for the readers with low or medium experience (AUC difference in detecting GS ≥ 3 + 4 compared to mpMRI: 0.06 [95% CI: -0.03, 0.14], <i>p</i> = 0.19 and 0.06 [95% CI: -0.03, 0.14], <i>p</i> = 0.19, respectively). <b>Conclusions:</b> This study indicates that AI-bpMRI detects PCa with a diagnostic accuracy comparable to that of mpMRI.

Journal of Clinical MedicineVol. 14(17)
Fuse (United States) (US), Jena University Hospital (DE), Martin Luther University Halle-Wittenberg (DE), Friedrich Schiller University Jena (DE)
Openalex Percentile: Top 8%
Prostate Cancer Diagnosis and Treatment
3.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.