Photopolymerization 3D-Printed Dual-Modal Flexible Sensor for Glucose and pH Monitoring

Currently, flexible sensors based on electrochemical principles are predominantly limited to single-parameter detection, making it challenging to meet the demand for synchronous monitoring of multiple analytes in complex physiological environments. This study presents a 3D-printed flexible sensor for synchronous glucose/pH detection. Glucose was quantified via H<sub>2</sub>O<sub>2</sub> oxidation current (GOD-catalyzed reaction), while pH was measured through polyaniline (PANI) resistance changes. The ionogel-based microneedle electrode ensures mechanical robustness. At 0.2 V, optimal signal decoupling was achieved: glucose oxidation current dominates, while PANI's polarization effect is minimized. Neutral pH minimally affected glucose oxidase (GOD) activity, and low glucose concentrations induced negligible pH interference, ensuring orthogonality. In artificial interstitial fluid, the sensor showed glucose: linear response (0.5-2.5 g·L<sup>-1</sup>, 0.288 μA·mM<sup>-1</sup>·cm<sup>-2</sup>); pH: piecewise-linear sensitivity (0.155 Ω/pH·cm<sup>2</sup> for pH > 7; 0.135 Ω/pH·cm<sup>2</sup> for pH < 7). The design enables real-time multiparameter monitoring with high selectivity, addressing current limitations in flexible electrochemical sensors.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-08-29
DOI
https://doi.org/10.3390/s25175358
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Photopolymerization 3D-Printed Dual-Modal Flexible Sensor for Glucose and pH Monitoring

Qiuzheng Li, Jiao Fu, Zhenyao Yang, Guangmeng Ma et al.
Sensors
Advanced Sensor and Energy Harvesting Materials
article

Photopolymerization 3D-Printed Dual-Modal Flexible Sensor for Glucose and pH Monitoring

Qiuzheng Li, Jiao Fu, Zhenyao Yang, Guangmeng Ma, Yu Long, Lin Shao, Yu Li, Baojun Pang, Feng Yin
article en

Abstract

Currently, flexible sensors based on electrochemical principles are predominantly limited to single-parameter detection, making it challenging to meet the demand for synchronous monitoring of multiple analytes in complex physiological environments. This study presents a 3D-printed flexible sensor for synchronous glucose/pH detection. Glucose was quantified via H<sub>2</sub>O<sub>2</sub> oxidation current (GOD-catalyzed reaction), while pH was measured through polyaniline (PANI) resistance changes. The ionogel-based microneedle electrode ensures mechanical robustness. At 0.2 V, optimal signal decoupling was achieved: glucose oxidation current dominates, while PANI's polarization effect is minimized. Neutral pH minimally affected glucose oxidase (GOD) activity, and low glucose concentrations induced negligible pH interference, ensuring orthogonality. In artificial interstitial fluid, the sensor showed glucose: linear response (0.5-2.5 g·L<sup>-1</sup>, 0.288 μA·mM<sup>-1</sup>·cm<sup>-2</sup>); pH: piecewise-linear sensitivity (0.155 Ω/pH·cm<sup>2</sup> for pH > 7; 0.135 Ω/pH·cm<sup>2</sup> for pH < 7). The design enables real-time multiparameter monitoring with high selectivity, addressing current limitations in flexible electrochemical sensors.

SensorsVol. 25(17)
Guangxi University (CN)
National Key Research and Development Program of China
Openalex Percentile: Top 79%
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.