Development of a 96-Well Plate Dithiothreitol Method for the Colorimetric Determination of Nickel Ions in Water Samples

A new, simple, and accurate assay was developed for the colorimetric determination of nickel ions in 96-well plates. The proposed method utilized the color change immediately visible even to the naked eye during the reaction of Ni(II) ions with dithiothreitol molecules (DTT). The intensity of the color produced by the formation of the complex between nickel and dithiothreitol is linearly proportional to the concentration of the metal ions in an alkaline environment, at room temperature, and the detection was performed using a mobile phone as the detector. The proposed method had a good linear response between 0.05 and 0.75 mmol L<sup>-1</sup> and a detection limit of 0.13 mmol L<sup>-1</sup> and was successfully applied for the determination of Ni(II) in bottled and surface water samples.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-08-29
DOI
https://doi.org/10.3390/s25175361
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a 96-Well Plate Dithiothreitol Method for the Colorimetric Determination of Nickel Ions in Water Samples

Maria Tarara, George Z. Tsogas, George N. Nikas
Sensors
Analytical chemistry methods development
article

Development of a 96-Well Plate Dithiothreitol Method for the Colorimetric Determination of Nickel Ions in Water Samples

Maria Tarara, George Z. Tsogas, George N. Nikas
article en

Abstract

A new, simple, and accurate assay was developed for the colorimetric determination of nickel ions in 96-well plates. The proposed method utilized the color change immediately visible even to the naked eye during the reaction of Ni(II) ions with dithiothreitol molecules (DTT). The intensity of the color produced by the formation of the complex between nickel and dithiothreitol is linearly proportional to the concentration of the metal ions in an alkaline environment, at room temperature, and the detection was performed using a mobile phone as the detector. The proposed method had a good linear response between 0.05 and 0.75 mmol L<sup>-1</sup> and a detection limit of 0.13 mmol L<sup>-1</sup> and was successfully applied for the determination of Ni(II) in bottled and surface water samples.

SensorsVol. 25(17)
Aristotle University of Thessaloniki (GR)
Openalex Percentile: Top 75%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.