Research on Multi-Model Switching Control of Linear Fresnel Heat Collecting Subsystem

Aiming at the stochasticity, uncertainty, and strong perturbation of the linear Fresnel solar thermal power collection subsystem, this study establishes a multivariate prediction model for the linear Fresnel collector subsystem based on complex environmental characteristics and designs a PID controller and MPC controller for the tracking and control of the outlet temperature. By analyzing the heat transfer process of the collector, constructing a model in Multiphysics for three-dimensional modeling of the collector, extracting data through simulation, fuzzy clustering the data and using different clustering centers for parameter identification in order to obtain the multi-model. By using the field data from the site of Dunhuang Dacheng Linear Fresnel Molten Salt Collector Field, considering the inlet temperature, normal direct irradiance and wind speed are used as the perturbation quantities, and the flow rate of molten salt is used as the control quantity. Considering three representative weather conditions, the switching criterion of minimizing the real-time point error is adopted for switching the outlet temperature of the collector. Simulation analysis results show that under the same conditions, the tracking error of the single model is relatively large, with the output temperature error fluctuating between −100 °C and 100 °C and containing many burrs. In contrast, the output temperature error of the multi-model switching control is controlled within 50 °C, which features a smaller tracking error and a faster tracking speed compared with the single-model control. When faced with large disturbances, the multi-model MPC switching control achieves better tracking performance than the multi-model PID switching control. It tracks temperatures closer to the set value, with a faster tracking speed and more excellent anti-interference performance.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2025-08-29
DOI
https://doi.org/10.3390/su17177780
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Multi-Model Switching Control of Linear Fresnel Heat Collecting Subsystem

Duojin Fan, Linggang Kong, Xiaoying Yu, Zhiyong Zhang et al.
Sustainability
Power Systems and Renewable Energy
article

Research on Multi-Model Switching Control of Linear Fresnel Heat Collecting Subsystem

Duojin Fan, Linggang Kong, Xiaoying Yu, Zhiyong Zhang, Xiaojuan Lu, Rui Yu
article en

Abstract

Aiming at the stochasticity, uncertainty, and strong perturbation of the linear Fresnel solar thermal power collection subsystem, this study establishes a multivariate prediction model for the linear Fresnel collector subsystem based on complex environmental characteristics and designs a PID controller and MPC controller for the tracking and control of the outlet temperature. By analyzing the heat transfer process of the collector, constructing a model in Multiphysics for three-dimensional modeling of the collector, extracting data through simulation, fuzzy clustering the data and using different clustering centers for parameter identification in order to obtain the multi-model. By using the field data from the site of Dunhuang Dacheng Linear Fresnel Molten Salt Collector Field, considering the inlet temperature, normal direct irradiance and wind speed are used as the perturbation quantities, and the flow rate of molten salt is used as the control quantity. Considering three representative weather conditions, the switching criterion of minimizing the real-time point error is adopted for switching the outlet temperature of the collector. Simulation analysis results show that under the same conditions, the tracking error of the single model is relatively large, with the output temperature error fluctuating between −100 °C and 100 °C and containing many burrs. In contrast, the output temperature error of the multi-model switching control is controlled within 50 °C, which features a smaller tracking error and a faster tracking speed compared with the single-model control. When faced with large disturbances, the multi-model MPC switching control achieves better tracking performance than the multi-model PID switching control. It tracks temperatures closer to the set value, with a faster tracking speed and more excellent anti-interference performance.

SustainabilityVol. 17(17)
Lanzhou Jiaotong University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 76%
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.