Design and Implement a Grid Forming Inverter with Low Harmonic Current Control

This paper proposes a control strategy suppressing 5<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">th</sup> and 7<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">th</sup> harmonics. Using Park's Transformation, the high-order harmonics of the grid can be extracted separately. The compensation current is then fed back into the grid to eliminate the harmonic components following the use of a controller and active power filter. This topology uses a 3-phase, three-level neutral point clamped inverter as the realization circuit of the active power filter. Compared with the conventional two-level inverter, this topology has the advantages of lower harmonic distortion and more minor switching voltage stress. Furthermore, SiC MOSFETs with lower conduction loss and switching losses are used as the main power switches to improve system efficiency. Finally, an experimental prototype inverter controlled by DSPTMS320F28335 is implemented with a rated power of 7.2kW, input voltage of 800 V, output voltage of 220 V<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">rms</inf> for each phase, switching frequency of 40 kHz, and line frequency of 60 Hz to verify the feasibility of the theory. The experiment results show that the 5<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">th</sup> and 7<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">th</sup> harmonic current is reduced to 3.26% and 3.48%, respectively, when added harmonic suppression control. Furthermore, the THD of the grid without compensation is 31.05%, and the THD after the 5<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">th</sup> and 7<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">th</sup> compensation is 5.41%.

Authors

Institutions

Publication Details

Published
2025-06-08
DOI
https://doi.org/10.1109/pvsc59419.2025.11132755
Primary Topic
Electric Motor Design and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Implement a Grid Forming Inverter with Low Harmonic Current Control

Y. Ye, Che-Wei Hsu, Jiann-Fuh Chen
Electric Motor Design and Analysis
article

Design and Implement a Grid Forming Inverter with Low Harmonic Current Control

Y. Ye, Che-Wei Hsu, Jiann-Fuh Chen
article en

Abstract

This paper proposes a control strategy suppressing 5<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">th</sup> and 7<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">th</sup> harmonics. Using Park's Transformation, the high-order harmonics of the grid can be extracted separately. The compensation current is then fed back into the grid to eliminate the harmonic components following the use of a controller and active power filter. This topology uses a 3-phase, three-level neutral point clamped inverter as the realization circuit of the active power filter. Compared with the conventional two-level inverter, this topology has the advantages of lower harmonic distortion and more minor switching voltage stress. Furthermore, SiC MOSFETs with lower conduction loss and switching losses are used as the main power switches to improve system efficiency. Finally, an experimental prototype inverter controlled by DSPTMS320F28335 is implemented with a rated power of 7.2kW, input voltage of 800 V, output voltage of 220 V<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">rms</inf> for each phase, switching frequency of 40 kHz, and line frequency of 60 Hz to verify the feasibility of the theory. The experiment results show that the 5<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">th</sup> and 7<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">th</sup> harmonic current is reduced to 3.26% and 3.48%, respectively, when added harmonic suppression control. Furthermore, the THD of the grid without compensation is 31.05%, and the THD after the 5<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">th</sup> and 7<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">th</sup> compensation is 5.41%.

National Cheng Kung University (TW)
Ministry of Education, National Science and Technology Council
Affordable and clean energy
Openalex Percentile: Top 78%
Electric Motor Design and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and Implement a Grid Forming Inverter with Low Harmonic Current Control — Y. Ye, Che-Wei Hsu, et al. · (2025) | TGRS Research Map | TGRS