Photovoltaic Module Backsheet Burns Attributed to Misaligned Busbar Wires

A photovoltaic module in an outdoor single-axis tracking, utility-scale field experienced a backsheet burn that exposed the rear of the cells and started a grass fire. The opening in the backsheet developed due to increased heating where the busbar wires stringing the cells together were offset from their original solder pad locations. Several other examples of similar backsheet burns were found at this installation, and some cases also show that thermal stress caused the front glass to crack and shatter. Photoluminescence, electroluminescence and thermal imaging techniques document the module performance and cell damage. Ultraviolet fluorescence provides time-dependent information to distinguish an older cell crack that developed with the backsheet melting from a newer crack that formed during the arc flash fire event and a scrape likely from handling to remove and transport the module. Microscopy analysis identifies the metal composition of the solder as Sn-Pb and not a Bi-containing low-temperature variety. Laser isolation of a cell contact area with misaligned wire shows intermittent contact quality, suggesting the module likely passed factory screening and showed no high contact resistance prior to aging in the field.

Authors

Institutions

Publication Details

Published
2025-06-08
DOI
https://doi.org/10.1109/pvsc59419.2025.11132961
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Photovoltaic Module Backsheet Burns Attributed to Misaligned Busbar Wires

Dana B. Kern, Rebecca B. Wai, Ingrid Repins, Harvey Guthrey et al.
Electrical Fault Detection and Protection
article

Photovoltaic Module Backsheet Burns Attributed to Misaligned Busbar Wires

Dana B. Kern, Rebecca B. Wai, Ingrid Repins, Harvey Guthrey, Steve Johnston, Steven P. Harvey
article en

Abstract

A photovoltaic module in an outdoor single-axis tracking, utility-scale field experienced a backsheet burn that exposed the rear of the cells and started a grass fire. The opening in the backsheet developed due to increased heating where the busbar wires stringing the cells together were offset from their original solder pad locations. Several other examples of similar backsheet burns were found at this installation, and some cases also show that thermal stress caused the front glass to crack and shatter. Photoluminescence, electroluminescence and thermal imaging techniques document the module performance and cell damage. Ultraviolet fluorescence provides time-dependent information to distinguish an older cell crack that developed with the backsheet melting from a newer crack that formed during the arc flash fire event and a scrape likely from handling to remove and transport the module. Microscopy analysis identifies the metal composition of the solder as Sn-Pb and not a Bi-containing low-temperature variety. Laser isolation of a cell contact area with misaligned wire shows intermittent contact quality, suggesting the module likely passed factory screening and showed no high contact resistance prior to aging in the field.

National Laboratory of the Rockies (US)
Affordable and clean energy
Openalex Percentile: Top 78%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Photovoltaic Module Backsheet Burns Attributed to Misaligned Busbar Wires — Dana B. Kern, Rebecca B. Wai, et al. · (2025) | TGRS Research Map | TGRS