High-Frequency Self-Synchronized Load-Independent Class-E Rectifier Using Fixed-Point Crossing Detection

This paper presents an intra-cycle self-synchronized load-independent (LI) class-E rectifier based on a novel fixedpoint crossing detection (FPXD) method. Through circuit analysis, we identify that the drain-to-source voltage of the LI class-E rectifier consistently crosses a fixed voltage threshold at a specific phase angle prior to turn-on, independent of load resistance. This fixed crossing point serves as a reliable trigger for gate-drive signal generation. Therefore, the proposed approach enables intracycle synchronization without the need for additional resonant components or control circuitry. Analytical expressions for the fixed point are derived, and a systematic design procedure is provided. A 6.78 MHz, 20 W WPT prototype was implemented and tested. The rectifier maintained robust load-independent performance, demonstrating nearly constant output voltage and input reactance across varying loads. Compared with the zerocrossing detection (ZXD)-based intra-cycle synchronization, the proposed method achieved more precise switching, eliminating reverse conduction and switching losses, and reducing total rectifier effectively.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Electronics
Published
2025-08-29
DOI
https://doi.org/10.1109/tpel.2025.3604090
Primary Topic
Optical Network Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Frequency Self-Synchronized Load-Independent Class-E Rectifier Using Fixed-Point Crossing Detection

Yutaro Komiyama, Hiroo Sekiya, Wenqi Zhu, Ayano Komanaka et al.
IEEE Transactions on Power Electronics
Optical Network Technologies
article

High-Frequency Self-Synchronized Load-Independent Class-E Rectifier Using Fixed-Point Crossing Detection

Yutaro Komiyama, Hiroo Sekiya, Wenqi Zhu, Ayano Komanaka, Kien Nguyen, Hirotaka Koizumi
article en

Abstract

This paper presents an intra-cycle self-synchronized load-independent (LI) class-E rectifier based on a novel fixedpoint crossing detection (FPXD) method. Through circuit analysis, we identify that the drain-to-source voltage of the LI class-E rectifier consistently crosses a fixed voltage threshold at a specific phase angle prior to turn-on, independent of load resistance. This fixed crossing point serves as a reliable trigger for gate-drive signal generation. Therefore, the proposed approach enables intracycle synchronization without the need for additional resonant components or control circuitry. Analytical expressions for the fixed point are derived, and a systematic design procedure is provided. A 6.78 MHz, 20 W WPT prototype was implemented and tested. The rectifier maintained robust load-independent performance, demonstrating nearly constant output voltage and input reactance across varying loads. Compared with the zerocrossing detection (ZXD)-based intra-cycle synchronization, the proposed method achieved more precise switching, eliminating reverse conduction and switching losses, and reducing total rectifier effectively.

IEEE Transactions on Power ElectronicsVol. 41(1)
Chiba University (JP), Tokyo University of Science (JP)
Openalex Percentile: Top 78%
Optical Network Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

High-Frequency Self-Synchronized Load-Independent Class-E Rectifier Using Fixed-Point Crossing Detection — Yutaro Komiyama, Hiroo Sekiya, et al. · IEEE Transactions on Power Electronics (2025) | TGRS Research Map | TGRS