Effective Dose Estimation with IDAC and OLINDA for 18F-FDG and 68Ga-PSMA PET/CT Procedures

Internal dosimetry is a part of radiation safety for patients and radiation workers in nuclear medicine procedures. This study retrospectively determined the effective dose for oncology patients undergoing PET/CT scans by using widely used computer codes, and the results were compared with each other and literature. The study focused on the radiopharmaceuticals 18 F-FDG (n = 220) and 68 Ga-PSMA (n = 85), administered to 305 patients for cancer imaging at Yeditepe University Kosuyolu Hospital's nuclear medicine department. PET dose was calculated using OLINDA/EXM, IDAC-Dose 1.0 and IDAC-Dose 2.1 programs while ImPACT software was used to determine the effective dose from the CT scan. All effective doses were derived in accordance with ICRP 60 and ICRP 103 tissue weighting factors. PET effective doses from highest to lowest were calculated with OLINDA/EXM, IDAC-Dose 1.0, IDAC-Dose 2.1 (ICRP 60) and IDAC-Dose 2.1 (ICRP 103) as 9.96, 9.07, 7.01, 6.28 mSv respectively for 18 F-FDG. The highest PET effective dose was also calculated with OLINDA/EXM software as 3.65 mSv for 68 Ga-PSMA. For the total effective dose in PET/CT scans, CT contributed about 92% for 68 Ga-PSMA protocol and 75% for 18 F-FDG protocol.

Authors

Institutions

Publication Details

Journal
Health Physics
Published
2025-08-29
DOI
https://doi.org/10.1097/hp.0000000000002034
Citations
1
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
1.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effective Dose Estimation with IDAC and OLINDA for 18F-FDG and 68Ga-PSMA PET/CT Procedures

Türkay Toklu, N. Altınsoy, Fatma Hilal Bikirli
1 citations
Health Physics
Radiation Dose and Imaging
1.36
article

Effective Dose Estimation with IDAC and OLINDA for 18F-FDG and 68Ga-PSMA PET/CT Procedures

Türkay Toklu, N. Altınsoy, Fatma Hilal Bikirli
article en
1 citations

Abstract

Internal dosimetry is a part of radiation safety for patients and radiation workers in nuclear medicine procedures. This study retrospectively determined the effective dose for oncology patients undergoing PET/CT scans by using widely used computer codes, and the results were compared with each other and literature. The study focused on the radiopharmaceuticals 18 F-FDG (n = 220) and 68 Ga-PSMA (n = 85), administered to 305 patients for cancer imaging at Yeditepe University Kosuyolu Hospital's nuclear medicine department. PET dose was calculated using OLINDA/EXM, IDAC-Dose 1.0 and IDAC-Dose 2.1 programs while ImPACT software was used to determine the effective dose from the CT scan. All effective doses were derived in accordance with ICRP 60 and ICRP 103 tissue weighting factors. PET effective doses from highest to lowest were calculated with OLINDA/EXM, IDAC-Dose 1.0, IDAC-Dose 2.1 (ICRP 60) and IDAC-Dose 2.1 (ICRP 103) as 9.96, 9.07, 7.01, 6.28 mSv respectively for 18 F-FDG. The highest PET effective dose was also calculated with OLINDA/EXM software as 3.65 mSv for 68 Ga-PSMA. For the total effective dose in PET/CT scans, CT contributed about 92% for 68 Ga-PSMA protocol and 75% for 18 F-FDG protocol.

Health PhysicsVol. 130(3)
Yeditepe University (TR), Istanbul Technical University (TR)
Openalex Percentile: Top 16%
Radiation Dose and Imaging
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effective Dose Estimation with IDAC and OLINDA for 18F-FDG and 68Ga-PSMA PET/CT Procedures — Türkay Toklu, N. Altınsoy, et al. · Health Physics (2025) | TGRS Research Map | TGRS