Validation of video-assisted computer vision goniometry to measure shoulder abduction motor function

Introduction Goniometry is used to measure shoulder abduction range of motion aiding in diagnosis, rehabilitation planning and monitoring progress in rehabilitation evaluating a patient's shoulder function. Computer vision technology holds promising potential for the assessment of movement by unifying and objectifying goniometric studies of different somatometric parameters. The objective was to validate a video-assisted computer vision goniometry of the motor function of shoulder abduction using the potential of neural networks. Material and methods The study involved 33 volunteers, males and females aged 18 to 56 years, with the weight of 53 to 108 kg and the height of 155 to 195 cm. Measurements of related samples were compared to validate the author's method of goniometric examination of shoulder abduction. Classical goniometry was used for patients of group 1. Changes in the shoulder position were radiologically explored in group 2 and video-assisted goniometry computer vision was employed for examinations in group 3. The study was performed using hardware and software "Arthro-Pro" system. Statistical processing was produced using the Statgraphics software package. Results The average difference in the abduction was insignificant in groups 1 and 2 measuring (0.62 ± 0.63)° from a minimum of 5.2° to a maximum of 1° with confidence interval of p = 0.95. The difference in the abduction angle ranged from -11.8° to 22.7° in groups 1 and 3 with the average difference of 6° and confidence interval of p = 0.95. Discussion The minor difference in the abduction angles obtained with computer vision technologies and classical goniometry indicated the comparability of the two methods facilitating the possibility of introducing artificial intelligence for assessing musculoskeletal function in clinical practice. Conclusion The video-assisted computer vision goniometry is practical for measurements of shoulder abduction in clinical practice.

Authors

Institutions

Publication Details

Journal
Genij Ortopedii
Published
2025-08-25
DOI
https://doi.org/10.18019/1028-4427-2025-31-4-424-432
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of video-assisted computer vision goniometry to measure shoulder abduction motor function

И. Э. Симонова, Аnastasya Malyakina, S. A. Demkin, О.А. Каплунов et al.
Genij Ortopedii
Shoulder Injury and Treatment
article

Validation of video-assisted computer vision goniometry to measure shoulder abduction motor function

И. Э. Симонова, Аnastasya Malyakina, S. A. Demkin, О.А. Каплунов, S. A. Akhramovich, I. E. Obramenko
article en

Abstract

Introduction Goniometry is used to measure shoulder abduction range of motion aiding in diagnosis, rehabilitation planning and monitoring progress in rehabilitation evaluating a patient's shoulder function. Computer vision technology holds promising potential for the assessment of movement by unifying and objectifying goniometric studies of different somatometric parameters. The objective was to validate a video-assisted computer vision goniometry of the motor function of shoulder abduction using the potential of neural networks. Material and methods The study involved 33 volunteers, males and females aged 18 to 56 years, with the weight of 53 to 108 kg and the height of 155 to 195 cm. Measurements of related samples were compared to validate the author's method of goniometric examination of shoulder abduction. Classical goniometry was used for patients of group 1. Changes in the shoulder position were radiologically explored in group 2 and video-assisted goniometry computer vision was employed for examinations in group 3. The study was performed using hardware and software "Arthro-Pro" system. Statistical processing was produced using the Statgraphics software package. Results The average difference in the abduction was insignificant in groups 1 and 2 measuring (0.62 ± 0.63)° from a minimum of 5.2° to a maximum of 1° with confidence interval of p = 0.95. The difference in the abduction angle ranged from -11.8° to 22.7° in groups 1 and 3 with the average difference of 6° and confidence interval of p = 0.95. Discussion The minor difference in the abduction angles obtained with computer vision technologies and classical goniometry indicated the comparability of the two methods facilitating the possibility of introducing artificial intelligence for assessing musculoskeletal function in clinical practice. Conclusion The video-assisted computer vision goniometry is practical for measurements of shoulder abduction in clinical practice.

Genij OrtopediiVol. 31(4)
Volgograd State Medical University (RU), Volgograd State Technical University (RU), Metacomp Technologies (United States) (US)
Openalex Percentile: Top 63%
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.