The dynamic changes in quantitative parameters of diffusion-weighted imaging at different b-values in a prostate cancer mouse model and their correlation with histopathology parameters

The aim of this study was to evaluate the dynamic variations in the quantitative parameters of diffusion-weighted imaging (DWI) at different b-value combinations in a prostate cancer (PCa) mouse model for noninvasive monitoring of histopathological changes. Twenty-five male C57BL/6J mice were randomly allocated into a control group (n=5) or an experimental group (n=20). The experimental groups were used to establish the PCa model. On days 9, 12, 15, and 18 post-modeling, 5 mice were randomly selected for MRI, including T1WI, T2WI, T2WI SPIR, and DWI. The b-values were set at 0, 500, 1000, 1500, and 2000 s/mm2. Apparent diffusion coefficient (ADC) and exponential apparent diffusion coefficient (EADC) values from different b-value combinations were measured. Post-MRI, tumors were excised for histopathological analysis. DWI quantitative parameters, tumor nuclear fraction, and Ki-67 area fraction were compared on different days, along with correlation analysis. ADC values gradually decreased as tumor progressed, whereas EADC values gradually increased. Tumor nuclear fraction increased over time. Ki-67 increased first and then decreased. Tumor nuclear fraction was negatively correlated with the ADC value and positively correlated with the EADC value. The Ki-67 was positively correlated with the ADC value and negatively correlated with the EADC value. ADC values at b=1000, 1500 s/mm2 and the EADC values at b=0, 500 s/mm2 demonstrated the strongest correlations with the tumor nuclear fraction; the ADC and EADC values at b=500, 1000 s/mm2 were more strongly correlated with Ki-67, being potential noninvasive imaging biomarkers for monitoring changes in tumor histopathology.

Authors

Institutions

Publication Details

Journal
Brazilian Journal of Medical and Biological Research
Published
2025-01-01
DOI
https://doi.org/10.1590/1414-431x2025e14527
Primary Topic
MRI in cancer diagnosis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The dynamic changes in quantitative parameters of diffusion-weighted imaging at different b-values in a prostate cancer mouse model and their correlation with histopathology parameters

X. Zhang, Mengmeng Zhang, Xin Zhou, Guohua Li et al.
Brazilian Journal of Medical and Biological Research
MRI in cancer diagnosis
article

The dynamic changes in quantitative parameters of diffusion-weighted imaging at different b-values in a prostate cancer mouse model and their correlation with histopathology parameters

X. Zhang, Mengmeng Zhang, Xin Zhou, Guohua Li, R. Zhang, Yida Li, Shengjian Sun
article en

Abstract

The aim of this study was to evaluate the dynamic variations in the quantitative parameters of diffusion-weighted imaging (DWI) at different b-value combinations in a prostate cancer (PCa) mouse model for noninvasive monitoring of histopathological changes. Twenty-five male C57BL/6J mice were randomly allocated into a control group (n=5) or an experimental group (n=20). The experimental groups were used to establish the PCa model. On days 9, 12, 15, and 18 post-modeling, 5 mice were randomly selected for MRI, including T1WI, T2WI, T2WI SPIR, and DWI. The b-values were set at 0, 500, 1000, 1500, and 2000 s/mm2. Apparent diffusion coefficient (ADC) and exponential apparent diffusion coefficient (EADC) values from different b-value combinations were measured. Post-MRI, tumors were excised for histopathological analysis. DWI quantitative parameters, tumor nuclear fraction, and Ki-67 area fraction were compared on different days, along with correlation analysis. ADC values gradually decreased as tumor progressed, whereas EADC values gradually increased. Tumor nuclear fraction increased over time. Ki-67 increased first and then decreased. Tumor nuclear fraction was negatively correlated with the ADC value and positively correlated with the EADC value. The Ki-67 was positively correlated with the ADC value and negatively correlated with the EADC value. ADC values at b=1000, 1500 s/mm2 and the EADC values at b=0, 500 s/mm2 demonstrated the strongest correlations with the tumor nuclear fraction; the ADC and EADC values at b=500, 1000 s/mm2 were more strongly correlated with Ki-67, being potential noninvasive imaging biomarkers for monitoring changes in tumor histopathology.

Brazilian Journal of Medical and Biological ResearchVol. 58
Qiqihar Medical University (CN)
Health Commission of Heilongjiang Province
Openalex Percentile: Top 68%
MRI in cancer diagnosis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.