Gas Chromatographic Determination of ppm-Level Carbon Tetrachloride in Wastewater Using a Flame Ionization Detector and Nitrogen Carrier Gas for Manufacturing Process Control

A simple and accurate analytical method was developed for determining carbon tetrachloride (CCl4) at the ppm level in wastewater from the manufacturing process as part of process monitoring and control. In this method, CCl4 was extracted from wastewater using toluene and analyzed by gas chromatography (GC) equipped with a flame ionization detector (FID) and an OVI-G43 capillary column (film thickness: 3 μm; inner diameter: 0.53 mm; and length: 30 m), with nitrogen as the carrier gas. The proposed method was validated in terms of its specificity, linearity, accuracy, and repeatability. The regression curve demonstrated excellent linearity (r = 1.000, r2 = 1.000) over a concentration range of 0.5–10 ppm. The mean recovery at concentrations between 0.5 and 5 ppm was 90 %, and the relative standard deviation for repeatability was 2.0 %. The limit of quantification was 0.5 ppm based on the linearity and accuracy results. The proposed method requires only simple liquid–liquid extraction, a versatile GC-FID system, and a sustainable carrier gas (nitrogen), making it highly suitable for the analysis of CCl4 at manufacturing sites.

Authors

Institutions

Publication Details

Journal
Chromatography
Published
2025-08-28
DOI
https://doi.org/10.15583/jpchrom.2025.013
Citations
1
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.75
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Gas Chromatographic Determination of ppm-Level Carbon Tetrachloride in Wastewater Using a Flame Ionization Detector and Nitrogen Carrier Gas for Manufacturing Process Control

Takashi Tokunaga, Makiko Mukumoto
1 citations
Chromatography
Analytical chemistry methods development
0.75
article

Gas Chromatographic Determination of ppm-Level Carbon Tetrachloride in Wastewater Using a Flame Ionization Detector and Nitrogen Carrier Gas for Manufacturing Process Control

Takashi Tokunaga, Makiko Mukumoto
article en
1 citations

Abstract

A simple and accurate analytical method was developed for determining carbon tetrachloride (CCl4) at the ppm level in wastewater from the manufacturing process as part of process monitoring and control. In this method, CCl4 was extracted from wastewater using toluene and analyzed by gas chromatography (GC) equipped with a flame ionization detector (FID) and an OVI-G43 capillary column (film thickness: 3 μm; inner diameter: 0.53 mm; and length: 30 m), with nitrogen as the carrier gas. The proposed method was validated in terms of its specificity, linearity, accuracy, and repeatability. The regression curve demonstrated excellent linearity (r = 1.000, r2 = 1.000) over a concentration range of 0.5–10 ppm. The mean recovery at concentrations between 0.5 and 5 ppm was 90 %, and the relative standard deviation for repeatability was 2.0 %. The limit of quantification was 0.5 ppm based on the linearity and accuracy results. The proposed method requires only simple liquid–liquid extraction, a versatile GC-FID system, and a sustainable carrier gas (nitrogen), making it highly suitable for the analysis of CCl4 at manufacturing sites.

ChromatographyVol. 46(3)
Sumitomo Chemical (Japan) (JP)
Clean water and sanitation
Openalex Percentile: Top 27%
Analytical chemistry methods development
0.75
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.