Development of a Physical Phantom for Occupational Eye Lens Dosimetry in a Non-homogeneous Radiation Field

Following the reduction in the occupational eye lens dose limit by the International Commission on Radiological Protection (ICRP), a physical phantom was developed to enable lens dose monitoring in complex radiation environments. The design is based on a validated eye model used to derive lens dose conversion coefficients. After evaluating various materials using Monte Carlo simulations, polymethyl methacrylate (PMMA) was selected for its ease of manufacturing and decontamination. The phantom's dose conversion coefficients were calculated for a range of photon energies and irradiation angles. Lens doses were measured using thermoluminescent dosimeter (TLD) chips embedded in the phantom and exposed to a 137 Cs reference field. Measurements were compared with simulation results, demonstrating good agreement. This newly developed PMMA phantom offers a practical solution for evaluating lens dose in non-uniform radiation fields such as those found in nuclear power plants.

Authors

Institutions

Publication Details

Journal
Health Physics
Published
2025-08-29
DOI
https://doi.org/10.1097/hp.0000000000002030
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Physical Phantom for Occupational Eye Lens Dosimetry in a Non-homogeneous Radiation Field

S. B. Cho, Hyunjun Na, Seungjin Choi, Jeong-In Kim et al.
1 links
Health Physics
Radiation Dose and Imaging
article

Development of a Physical Phantom for Occupational Eye Lens Dosimetry in a Non-homogeneous Radiation Field

S. B. Cho, Hyunjun Na, Seungjin Choi, Jeong-In Kim, Seokon Kang
article en

Abstract

Following the reduction in the occupational eye lens dose limit by the International Commission on Radiological Protection (ICRP), a physical phantom was developed to enable lens dose monitoring in complex radiation environments. The design is based on a validated eye model used to derive lens dose conversion coefficients. After evaluating various materials using Monte Carlo simulations, polymethyl methacrylate (PMMA) was selected for its ease of manufacturing and decontamination. The phantom's dose conversion coefficients were calculated for a range of photon energies and irradiation angles. Lens doses were measured using thermoluminescent dosimeter (TLD) chips embedded in the phantom and exposed to a 137 Cs reference field. Measurements were compared with simulation results, demonstrating good agreement. This newly developed PMMA phantom offers a practical solution for evaluating lens dose in non-uniform radiation fields such as those found in nuclear power plants.

Health PhysicsVol. 130(3)
Korea Electric Power Corporation (South Korea) (KR), Korea National Institute of Health (KR)
Openalex Percentile: Top 68%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.