Microfluidic electrochemical sensor with lead ion-imprinted polymer membrane for selective trace lead detection in water

Lead contamination in water remains a critical global concern due to its toxicity and persistence. We present a microfluidic sensor that integrates a stand-alone lead ion-imprinted polymer (Pb-IIP) membrane for selective lead detection. Synthesized in situ with Pb(II) as the template, methacrylic acid as the monomer, and 8-hydroxyquinoline as the ligand, the membrane acts as a selective affinity element embedded between non-functionalized electrodes. Leveraging imprinted cavity sites and the Pb-IIP's chemical affinity, the integrated sensor demonstrated heightened lead ion sensitivity, achieving a detection limit of 7.3 ppb and consistent quantification up to 100 ppm. Detection responses were 6.1-fold higher than the membrane-less sensor, 1.5-fold higher than the MAA-based non-imprinted polymer (NIP) sensor, and 13-fold higher than the acrylamide (AAM)-based NIP sensor. The Pb-IIP membrane also differentiated Pb(II) from Cd(II) and Zn(II), with Pb(II) responses being 12.5 % to 69.4 % higher than other ions. Validation with unfiltered municipal tap water yielded recoveries between 96.6 % and 109.0 %, with relative standard deviations below 7 %. These results demonstrate regulatory-relevant detection performance using a low-cost, easily fabricated platform suitable for future adaptation to portable, field-deployable systems. A low-cost microfluidic sensor integrates a stand-alone Pb-ion imprinted polymer (Pb-IIP) membrane for selective trace lead detection in water. Pb²⁺ ions bind selectively to imprinted cavities, generating a stronger electrochemical response than Cd²⁺, Zn²⁺, and blank controls. • Microfluidic sensor with stand-alone Pb-IIP membrane for lead detection. • In-situ synthesized Pb-IIP enables selective trace Pb 2+ sensing in water. • Strong Pb 2+ selectivity in single-ion, multi-ion, and real water samples. • Low-cost, adaptable sensor design for point-of-need heavy metal testing. • Validated in municipal water: 96.6–109.0 % recovery, <7 % RSD across replicates.

Authors

Institutions

Publication Details

Journal
Journal of Water Process Engineering
Published
2025-08-29
DOI
https://doi.org/10.1016/j.jwpe.2025.108574
Citations
4
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
2.06

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microfluidic electrochemical sensor with lead ion-imprinted polymer membrane for selective trace lead detection in water

Ayobami Elisha Oseyemi, Pouya Rezai
4 citations
Journal of Water Process Engineering
Electrochemical Analysis and Applications
2.06
article

Microfluidic electrochemical sensor with lead ion-imprinted polymer membrane for selective trace lead detection in water

Ayobami Elisha Oseyemi, Pouya Rezai
article en
4 citations

Abstract

Lead contamination in water remains a critical global concern due to its toxicity and persistence. We present a microfluidic sensor that integrates a stand-alone lead ion-imprinted polymer (Pb-IIP) membrane for selective lead detection. Synthesized in situ with Pb(II) as the template, methacrylic acid as the monomer, and 8-hydroxyquinoline as the ligand, the membrane acts as a selective affinity element embedded between non-functionalized electrodes. Leveraging imprinted cavity sites and the Pb-IIP's chemical affinity, the integrated sensor demonstrated heightened lead ion sensitivity, achieving a detection limit of 7.3 ppb and consistent quantification up to 100 ppm. Detection responses were 6.1-fold higher than the membrane-less sensor, 1.5-fold higher than the MAA-based non-imprinted polymer (NIP) sensor, and 13-fold higher than the acrylamide (AAM)-based NIP sensor. The Pb-IIP membrane also differentiated Pb(II) from Cd(II) and Zn(II), with Pb(II) responses being 12.5 % to 69.4 % higher than other ions. Validation with unfiltered municipal tap water yielded recoveries between 96.6 % and 109.0 %, with relative standard deviations below 7 %. These results demonstrate regulatory-relevant detection performance using a low-cost, easily fabricated platform suitable for future adaptation to portable, field-deployable systems. A low-cost microfluidic sensor integrates a stand-alone Pb-ion imprinted polymer (Pb-IIP) membrane for selective trace lead detection in water. Pb²⁺ ions bind selectively to imprinted cavities, generating a stronger electrochemical response than Cd²⁺, Zn²⁺, and blank controls. • Microfluidic sensor with stand-alone Pb-IIP membrane for lead detection. • In-situ synthesized Pb-IIP enables selective trace Pb 2+ sensing in water. • Strong Pb 2+ selectivity in single-ion, multi-ion, and real water samples. • Low-cost, adaptable sensor design for point-of-need heavy metal testing. • Validated in municipal water: 96.6–109.0 % recovery, <7 % RSD across replicates.

Journal of Water Process EngineeringVol. 77
York University (CA)
Mitacs, Natural Sciences and Engineering Research Council of Canada
Clean water and sanitation
Openalex Percentile: Top 12%
Electrochemical Analysis and Applications
2.06
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.