Deep Learning-Based Synthetic-CT Generation from MRI for Enhanced Precision in MRI-Only Radiotherapy Dose Planning

Abstract Introduction Radiotherapy aims to precisely target tumors while sparing healthy tissue, traditionally relying on CT imaging for accurate dose planning. However, CT has limitations in soft tissue contrast and exposes patients to ionizing radiation. MRI offers superior soft tissue contrast without radiation but lacks electron density information, restricting its use in dose planning. This study addresses this gap by developing deep learning models to generate pseudo-CT images from MRI, enabling MRI-only workflows in radiotherapy. Methodology Paired MRI and CT scans from 12 subjects were processed using normalization, alignment, and masking. Four deep learning architectures (U-Net, Pix2Pix, CycleGAN, and conditional GAN (cGAN)) were trained to generate synthetic CT images from MRI data. Model performance was evaluated using metrics including mean absolute error (MAE), mean squared error (MSE), peak signal-to-noise ratio (PSNR), structural similarity index (SSIM), and Pearson correlation coefficient (PCC). Results Pix2Pix achieved the highest SSIM and PSNR, indicating strong structural preservation and reduced noise. It also had the lowest MAE and MSE, showing high accuracy in synthetic-CT generation. The cGAN model scored highest in PCC, highlighting its effective intensity alignment with real CT data. Statistical tests confirmed Pix2Pix’s superior performance, though CycleGAN and cGAN also showed notable results in alignment accuracy. Conclusion Deep learning models, particularly Pix2Pix, can generate reliable pseudo-CT images from MRI, supporting MRI-only radiotherapy planning. This approach reduces radiation exposure and may streamline radiotherapy work-flows, offering a promising advance for patient-centered cancer care and MRI-only radiotherapy workflows.

Authors

Institutions

Publication Details

Journal
Polish Journal of Medical Physics And Engineering
Published
2025-08-28
DOI
https://doi.org/10.2478/pjmpe-2025-0025
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep Learning-Based Synthetic-CT Generation from MRI for Enhanced Precision in MRI-Only Radiotherapy Dose Planning

Samuel Nii Adu Tagoe, Isaac Kwesi Acquah, Issahaku Shirazu, Theophilus A. Sackey
Polish Journal of Medical Physics And Engineering
Advanced Radiotherapy Techniques
article

Deep Learning-Based Synthetic-CT Generation from MRI for Enhanced Precision in MRI-Only Radiotherapy Dose Planning

Samuel Nii Adu Tagoe, Isaac Kwesi Acquah, Issahaku Shirazu, Theophilus A. Sackey
article en

Abstract

Abstract Introduction Radiotherapy aims to precisely target tumors while sparing healthy tissue, traditionally relying on CT imaging for accurate dose planning. However, CT has limitations in soft tissue contrast and exposes patients to ionizing radiation. MRI offers superior soft tissue contrast without radiation but lacks electron density information, restricting its use in dose planning. This study addresses this gap by developing deep learning models to generate pseudo-CT images from MRI, enabling MRI-only workflows in radiotherapy. Methodology Paired MRI and CT scans from 12 subjects were processed using normalization, alignment, and masking. Four deep learning architectures (U-Net, Pix2Pix, CycleGAN, and conditional GAN (cGAN)) were trained to generate synthetic CT images from MRI data. Model performance was evaluated using metrics including mean absolute error (MAE), mean squared error (MSE), peak signal-to-noise ratio (PSNR), structural similarity index (SSIM), and Pearson correlation coefficient (PCC). Results Pix2Pix achieved the highest SSIM and PSNR, indicating strong structural preservation and reduced noise. It also had the lowest MAE and MSE, showing high accuracy in synthetic-CT generation. The cGAN model scored highest in PCC, highlighting its effective intensity alignment with real CT data. Statistical tests confirmed Pix2Pix’s superior performance, though CycleGAN and cGAN also showed notable results in alignment accuracy. Conclusion Deep learning models, particularly Pix2Pix, can generate reliable pseudo-CT images from MRI, supporting MRI-only radiotherapy planning. This approach reduces radiation exposure and may streamline radiotherapy work-flows, offering a promising advance for patient-centered cancer care and MRI-only radiotherapy workflows.

Polish Journal of Medical Physics And EngineeringVol. 31(3)
University of Ghana (GH), University of Education, Winneba (GH), Korle Bu Teaching Hospital (GH), Ghana Atomic Energy Commission (GH)
University of Ghana
Openalex Percentile: Top 71%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.