Detecting Elemental Impurities by Inductively Coupled Plasma Mass Spectrometry in Russian Radiopharmaceuticals

INTRODUCTION . Radiopharmaceutical manufacturers should assess potential negative impact of elemental impurities on the quality of their products using real data of their elemental contamination. Accumulating knowledge about medicinal products and their manufacturing process should start from the development stage and continue throughout the implementation stage until production finally ends. AIM . This study aimed to monitor elemental impurities content in Russian radiopharmaceuticals using inductively coupled plasma mass spectrometry. MATERIALS AND METHODS . The samples included 127 Russian radiopharmaceuticals obtained by the Scientific Center for Expert Evaluation of Medicinal Products during its statutory activities: fluorodeoxyglucose ( 18 F), PSMA-1007 ( 18 F), sodium iodide ( 131 I), sodium iodohippurate ( 131 I), iobenguane ( 123 I), and sodium pertechnetate ( 99m Tc). The content of Ag, Al, As, Au, Ba, Be, Bi, Cd, Co, Cr, Cu, Fe, Ga, Ge, Hg, Ir, Li, Mn, Nb, Ni, Os, Pb, Pd, Pt, Rh, Ru, Sb, Se, Mo, Sn, Tl, V, W, and Zn was detected on the Agilent 7900 mass spectrometer. RESULTS . Elemental impurities Ag, As, Au, Bi, Be, Cd, Co, Cr, Ga, Ge, Hg, Ir, Mo, Nb, Ni, Os, Pb, Pd, Pt, Rh, Ru, Sb, Se, Sn, Tl, V, and W were not detected in any of the tested radiopharmaceuticals. Al, Zn, and Cu mostly contributed to elemental contamination in almost all radiopharmaceuticals. Radiopharmaceuticals used for single-photon emission computed tomography (SPECT) contained significantly less elemental impurities compared to positron emission tomography (PET) radiopharmaceuticals. CONCLUSIONS . The elements that mostly contaminate Russian radiopharmaceuticals are non-toxic or low-toxic (Al, Zn, Cu). These impurities should be monitored in case they negatively impact the quality of radiopharmaceuticals. In fluorodeoxyglucose ( 18 F), elemental contamination heavily depends on the used buffer solution. In order to find out elemental contamination sources in the studied radiopharmaceuticals, an additional analysis of impurities in the raw materials, reagents and semi-products is indispensable at all technological stages.

Authors

Publication Details

Journal
Regulâtornye issledovaniâ i èkspertiza lekarstvennyh sredstv.
Published
2025-08-28
DOI
https://doi.org/10.30895/1991-2919-2025-15-4-434-443
Citations
1
Primary Topic
Radioactive element chemistry and processing
Type
article
Field-Weighted Citation Impact
0.54
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detecting Elemental Impurities by Inductively Coupled Plasma Mass Spectrometry in Russian Radiopharmaceuticals

Yu. N. Shvetsova, В. М. Щукин, А. А. Ерина, Н. Е. Кузьмина et al.
1 citations
Regulâtornye issledovaniâ i èkspertiza lekarstvennyh sredstv.
Radioactive element chemistry and processing
0.54
article

Detecting Elemental Impurities by Inductively Coupled Plasma Mass Spectrometry in Russian Radiopharmaceuticals

Yu. N. Shvetsova, В. М. Щукин, А. А. Ерина, Н. Е. Кузьмина, R. D. Ruziev, D. A. Pripadchev, M. A. Kuznetsov
article en
1 citations

Abstract

INTRODUCTION . Radiopharmaceutical manufacturers should assess potential negative impact of elemental impurities on the quality of their products using real data of their elemental contamination. Accumulating knowledge about medicinal products and their manufacturing process should start from the development stage and continue throughout the implementation stage until production finally ends. AIM . This study aimed to monitor elemental impurities content in Russian radiopharmaceuticals using inductively coupled plasma mass spectrometry. MATERIALS AND METHODS . The samples included 127 Russian radiopharmaceuticals obtained by the Scientific Center for Expert Evaluation of Medicinal Products during its statutory activities: fluorodeoxyglucose ( 18 F), PSMA-1007 ( 18 F), sodium iodide ( 131 I), sodium iodohippurate ( 131 I), iobenguane ( 123 I), and sodium pertechnetate ( 99m Tc). The content of Ag, Al, As, Au, Ba, Be, Bi, Cd, Co, Cr, Cu, Fe, Ga, Ge, Hg, Ir, Li, Mn, Nb, Ni, Os, Pb, Pd, Pt, Rh, Ru, Sb, Se, Mo, Sn, Tl, V, W, and Zn was detected on the Agilent 7900 mass spectrometer. RESULTS . Elemental impurities Ag, As, Au, Bi, Be, Cd, Co, Cr, Ga, Ge, Hg, Ir, Mo, Nb, Ni, Os, Pb, Pd, Pt, Rh, Ru, Sb, Se, Sn, Tl, V, and W were not detected in any of the tested radiopharmaceuticals. Al, Zn, and Cu mostly contributed to elemental contamination in almost all radiopharmaceuticals. Radiopharmaceuticals used for single-photon emission computed tomography (SPECT) contained significantly less elemental impurities compared to positron emission tomography (PET) radiopharmaceuticals. CONCLUSIONS . The elements that mostly contaminate Russian radiopharmaceuticals are non-toxic or low-toxic (Al, Zn, Cu). These impurities should be monitored in case they negatively impact the quality of radiopharmaceuticals. In fluorodeoxyglucose ( 18 F), elemental contamination heavily depends on the used buffer solution. In order to find out elemental contamination sources in the studied radiopharmaceuticals, an additional analysis of impurities in the raw materials, reagents and semi-products is indispensable at all technological stages.

Regulâtornye issledovaniâ i èkspertiza lekarstvennyh sredstv.Vol. 15(4)
Openalex Percentile: Top 32%
Radioactive element chemistry and processing
0.54
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.