Microcrack-Enhanced PEDOT:PSS Textile for Rapid-Response, Stable, and Breathable Wearable Sensors

The lightweight, wearable, comfortable, and high-performance sensors are crucial for future wearable electronics to facilitate the real-time monitoring of human health. In this paper, the textile-based flexible dry sensor is fabricated by coating waterborne polyurethane (WPU) enhanced poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) onto the commercial polyester fabric (PF). The WPU, containing both hard and soft segments, was synthesized by using the three-step acetaldehyde method. When the hard segment content was 30 wt %, it promoted better connectivity in the PEDOT regions, resulting in higher conductivity. Benefiting from the interaction among polymer chains of WPU and PEDOT:PSS, which enhances the orientation of PEDOT and phase separation of PEDOT with PSS, the PEDOT:PSS/WPU (PW) composite materials achieved conductivity as high as 3000 S cm<sup>-1</sup> after being treated with sulfuric acid (H<sub>2</sub>SO<sub>4</sub>). As a result, the PW-coated fabric (PWF) achieved the lowest resistance value of 71.69 Ω sq at room temperature. Notably, by prestretching of the stretchable PWF, the microcracks are induced on the PW coating, which optimize the internal structure and stress distribution and therefore endow the PWF with superior sensitivity and stability, enabling it to respond within 80 ms (at 400 Pa pressure) and maintain stability under multiple compression cycles (100 Pa) at frequencies between 0.05 and 0.5 Hz. Additionally, the prestretching process endows the PWF with a higher water vapor transmission rate (23.8 kg m<sup>-2</sup> d<sup>-1</sup>) than the pristine fabrics, despite the reduced conductivity and mechanical integrity. The as-fabricated PWF shows great potential for wearable body motion and electrocardiogram monitoring.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-08-29
DOI
https://doi.org/10.1021/acssensors.5c01556
Citations
2
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
1.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microcrack-Enhanced PEDOT:PSS Textile for Rapid-Response, Stable, and Breathable Wearable Sensors

Liya Huang, Yuan Liao, Tongqing Zhou, Wenkun Fei et al.
2 citations
ACS Sensors
Advanced Sensor and Energy Harvesting Materials
1.35
article

Microcrack-Enhanced PEDOT:PSS Textile for Rapid-Response, Stable, and Breathable Wearable Sensors

Liya Huang, Yuan Liao, Tongqing Zhou, Wenkun Fei, Jianmin Li, Yang Li, Yuxiang Zhang, Weilin Liu, Yuzhe Gu, Zixuan Zhang
article en
2 citations

Abstract

The lightweight, wearable, comfortable, and high-performance sensors are crucial for future wearable electronics to facilitate the real-time monitoring of human health. In this paper, the textile-based flexible dry sensor is fabricated by coating waterborne polyurethane (WPU) enhanced poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) onto the commercial polyester fabric (PF). The WPU, containing both hard and soft segments, was synthesized by using the three-step acetaldehyde method. When the hard segment content was 30 wt %, it promoted better connectivity in the PEDOT regions, resulting in higher conductivity. Benefiting from the interaction among polymer chains of WPU and PEDOT:PSS, which enhances the orientation of PEDOT and phase separation of PEDOT with PSS, the PEDOT:PSS/WPU (PW) composite materials achieved conductivity as high as 3000 S cm<sup>-1</sup> after being treated with sulfuric acid (H<sub>2</sub>SO<sub>4</sub>). As a result, the PW-coated fabric (PWF) achieved the lowest resistance value of 71.69 Ω sq at room temperature. Notably, by prestretching of the stretchable PWF, the microcracks are induced on the PW coating, which optimize the internal structure and stress distribution and therefore endow the PWF with superior sensitivity and stability, enabling it to respond within 80 ms (at 400 Pa pressure) and maintain stability under multiple compression cycles (100 Pa) at frequencies between 0.05 and 0.5 Hz. Additionally, the prestretching process endows the PWF with a higher water vapor transmission rate (23.8 kg m<sup>-2</sup> d<sup>-1</sup>) than the pristine fabrics, despite the reduced conductivity and mechanical integrity. The as-fabricated PWF shows great potential for wearable body motion and electrocardiogram monitoring.

ACS SensorsVol. 10(9)
Nanjing University of Posts and Telecommunications (CN), Institute for the Future (US), Institute of Advanced Manufacturing Technology (CN)
National Natural Science Foundation of China, Natural Science Foundation of Jiangsu Province, Nanjing University of Posts and Telecommunications
Openalex Percentile: Top 18%
Advanced Sensor and Energy Harvesting Materials
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.