A comparative study of flexible electrode design on the performance of flexible wearable electronics

Flexible wearable electronics are promising for continuous health monitoring, particularly in electromyography (EMG) applications. A critical factor in their performance is electrode design, which affects mechanical resilience and electrical stability. Here, this study develops multiple electrode geometries: open-mesh, closed-mesh, and island-bridge, fabricated from gold-coated polyimide substrates to offer the best performance in EMG detection. Under standardized bending and stretching tests, the island-bridge design shows the lowest resistance variation (±1.61%), while the closed-mesh design provides balanced performance across various strains. EMG tests indicate that the closed-mesh electrodes deliver the highest signal-to-noise ratios (up to 14.83 dB) with minimal motion artifacts. Although the open-mesh design is flexible, it has lower electrical stability. In summary, the closed-mesh performs best overall, the open-mesh is better for handling motion artifacts, and the island-bridge is ideal for areas with minimal movement.

Authors

Institutions

Publication Details

Journal
Frontiers in Nanotechnology
Published
2025-08-29
DOI
https://doi.org/10.3389/fnano.2025.1632279
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A comparative study of flexible electrode design on the performance of flexible wearable electronics

Woon‐Hong Yeo, Asif Khan, Seunghyeb Ban, Jong‐Hoon Kim
Frontiers in Nanotechnology
Advanced Sensor and Energy Harvesting Materials
article

A comparative study of flexible electrode design on the performance of flexible wearable electronics

Woon‐Hong Yeo, Asif Khan, Seunghyeb Ban, Jong‐Hoon Kim
article en

Abstract

Flexible wearable electronics are promising for continuous health monitoring, particularly in electromyography (EMG) applications. A critical factor in their performance is electrode design, which affects mechanical resilience and electrical stability. Here, this study develops multiple electrode geometries: open-mesh, closed-mesh, and island-bridge, fabricated from gold-coated polyimide substrates to offer the best performance in EMG detection. Under standardized bending and stretching tests, the island-bridge design shows the lowest resistance variation (±1.61%), while the closed-mesh design provides balanced performance across various strains. EMG tests indicate that the closed-mesh electrodes deliver the highest signal-to-noise ratios (up to 14.83 dB) with minimal motion artifacts. Although the open-mesh design is flexible, it has lower electrical stability. In summary, the closed-mesh performs best overall, the open-mesh is better for handling motion artifacts, and the island-bridge is ideal for areas with minimal movement.

Frontiers in NanotechnologyVol. 7
Georgia Institute of Technology (US), Washington State University Vancouver (US), University of Washington (US), The Wallace H. Coulter Department of Biomedical Engineering (US)
Washington State University
Openalex Percentile: Top 79%
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A comparative study of flexible electrode design on the performance of flexible wearable electronics — Woon‐Hong Yeo, Asif Khan, et al. · Frontiers in Nanotechnology (2025) | TGRS Research Map | TGRS