Design and modeling of eye-shaped double-slot GaAs microring resonator for CO2 sensing

Monitoring of CO<sub>2</sub> is crucial because of its profound impact on both environmental and human health. A novel highly sensitive refractive index (RI) sensor, utilizing a double-slot microring resonating structure, has been designed and numerically assessed for the sensitive detection of gas media. The structure consisted of a circular microring resonator nested in a racetrack resonating configuration mimicking the structure of an eye-shaped microring resonator (ESMRR). This system was simulated and designed for a GaAs double-slot core waveguide deposited on a suitable Al<sub>0.5</sub>Ga<sub>0.5</sub>As substrate. Optical transfer function of ESMRR and related equations were derived using Mason rule, while the numerical analysis was performed using the variational finite difference time domain (var- FDTD) method. The free spectral range (FSR) was extended to 137.68 nm that led to a remarkable bulk sensitivity of 1217.39 nm/RIU and a resolution of 4.93 × 10<sup>-6</sup> RIU. The proposed sensing structure was envisioned for CO<sub>2</sub> sensing and demonstrated an impressive sensitivity of 24.4 pm/ppm for CO<sub>2</sub> detection with an estimated detection limit of 0.82 ppm.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-08-29
DOI
https://doi.org/10.1038/s41598-025-17208-6
Primary Topic
Photonic and Optical Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and modeling of eye-shaped double-slot GaAs microring resonator for CO2 sensing

Mahdi Bahadoran, Faezeh Pakfetrat, Francesco Chiavaioli, Shadab Dabagh
4 links
Scientific Reports
Photonic and Optical Devices
article

Design and modeling of eye-shaped double-slot GaAs microring resonator for CO2 sensing

Mahdi Bahadoran, Faezeh Pakfetrat, Francesco Chiavaioli, Shadab Dabagh
article en

Abstract

Monitoring of CO<sub>2</sub> is crucial because of its profound impact on both environmental and human health. A novel highly sensitive refractive index (RI) sensor, utilizing a double-slot microring resonating structure, has been designed and numerically assessed for the sensitive detection of gas media. The structure consisted of a circular microring resonator nested in a racetrack resonating configuration mimicking the structure of an eye-shaped microring resonator (ESMRR). This system was simulated and designed for a GaAs double-slot core waveguide deposited on a suitable Al<sub>0.5</sub>Ga<sub>0.5</sub>As substrate. Optical transfer function of ESMRR and related equations were derived using Mason rule, while the numerical analysis was performed using the variational finite difference time domain (var- FDTD) method. The free spectral range (FSR) was extended to 137.68 nm that led to a remarkable bulk sensitivity of 1217.39 nm/RIU and a resolution of 4.93 × 10<sup>-6</sup> RIU. The proposed sensing structure was envisioned for CO<sub>2</sub> sensing and demonstrated an impressive sensitivity of 24.4 pm/ppm for CO<sub>2</sub> detection with an estimated detection limit of 0.82 ppm.

Scientific ReportsVol. 15(1)
Shiraz University of Technology (IR), Nello Carrara Institute of Applied Physics (IT), Eskişehir Osmangazi University (TR)
Affordable and clean energy
Openalex Percentile: Top 78%
Photonic and Optical Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.