A three-dimensional finite element analysis of removable partial denture restoration: a comparison study of the combined impression <i>versus</i> the traditional open impression techniques

This study aimed to evaluate the mechanical behavior of a removable partial denture (RPD) using a new technique of impression-the combined impression technique (CIT)-via three-dimensional finite element analysis (FEA). A patient was selected to have removable partial dentures fabricated using CIT and the open-mouth impression technique (OIT), and the results were compared through FEA. Compared to OIT, CIT resulted in lower von Mises stresses on abutment teeth and alveolar ridges, with no significant stress concentrations and more balanced mucosal displacement in edentulous areas. CIT proved promising as it presented more favorable results than OIT in this simulation.

Authors

Institutions

Publication Details

Journal
Computer Methods in Biomechanics & Biomedical Engineering
Published
2025-08-28
DOI
https://doi.org/10.1080/10255842.2025.2551015
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A three-dimensional finite element analysis of removable partial denture restoration: a comparison study of the combined impression versus the traditional open impression techniques

Shuai Zhang, Xiangyu Cheng, Jingtong Wu, Liping Ren
Computer Methods in Biomechanics & Biomedical Engineering
Dental materials and restorations
article

A three-dimensional finite element analysis of removable partial denture restoration: a comparison study of the combined impression versus the traditional open impression techniques

Shuai Zhang, Xiangyu Cheng, Jingtong Wu, Liping Ren
article en

Abstract

This study aimed to evaluate the mechanical behavior of a removable partial denture (RPD) using a new technique of impression-the combined impression technique (CIT)-via three-dimensional finite element analysis (FEA). A patient was selected to have removable partial dentures fabricated using CIT and the open-mouth impression technique (OIT), and the results were compared through FEA. Compared to OIT, CIT resulted in lower von Mises stresses on abutment teeth and alveolar ridges, with no significant stress concentrations and more balanced mucosal displacement in edentulous areas. CIT proved promising as it presented more favorable results than OIT in this simulation.

Computer Methods in Biomechanics & Biomedical Engineering
Harbin Medical University (CN), First Affiliated Hospital of Harbin Medical University (CN)
Openalex Percentile: Top 76%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.