Fast and accurate measurement of high aspect ratio MEMS trench array with optical lattice illumination

The high aspect ratio (HAR) micro-electro-mechanical system trench array is a key component for the miniaturization of micro sensors, actuators, and other advanced precision equipment, with broad application prospects in defense, security, aerospace, energy, and other fields. Therefore, accurate and efficient measurement of the aspect ratio of microstructures will become a crucial method for monitoring and ensuring the reliability and stability of the device fabrication process. This paper presents a novel method that combines the lattice light field generated by a micro-axicon array with microscopic imaging technology to accurately measure the width and depth of HAR micro-trench structures. We designed and constructed a dedicated experimental system, initially using monochromatic microscopic imaging and edge extraction algorithms to obtain the width information of the trenches. Subsequently, the trench depth was measured using the diffraction lattice light field generated by the micro-axicon array. Experimental results indicate that as the light field propagates from the top to the bottom of the trench, the light spots in the lattice light field shift in position due to the presence of diffraction angles, with the displacement being closely related to the trench depth. A mapping between the displacement and depth is established through geometric relationships, enabling the calculation of the trench depth. We tested nine trench samples with different aspect ratios, with the maximum aspect ratio reaching 58.12. The experimental results, compared with the scanning electron microscope measurement values, show that the measurement errors are all <9%.

Authors

Institutions

Publication Details

Journal
Microsystems & Nanoengineering
Published
2025-08-28
DOI
https://doi.org/10.1038/s41378-025-01017-y
Citations
2
Primary Topic
Force Microscopy Techniques and Applications
Type
article
Field-Weighted Citation Impact
2.49

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fast and accurate measurement of high aspect ratio MEMS trench array with optical lattice illumination

Dengfeng Kuang, Xu Li, Xinqi Sui
2 citations
Microsystems & Nanoengineering
Force Microscopy Techniques and Applications
2.49
article

Fast and accurate measurement of high aspect ratio MEMS trench array with optical lattice illumination

Dengfeng Kuang, Xu Li, Xinqi Sui
article en
2 citations

Abstract

The high aspect ratio (HAR) micro-electro-mechanical system trench array is a key component for the miniaturization of micro sensors, actuators, and other advanced precision equipment, with broad application prospects in defense, security, aerospace, energy, and other fields. Therefore, accurate and efficient measurement of the aspect ratio of microstructures will become a crucial method for monitoring and ensuring the reliability and stability of the device fabrication process. This paper presents a novel method that combines the lattice light field generated by a micro-axicon array with microscopic imaging technology to accurately measure the width and depth of HAR micro-trench structures. We designed and constructed a dedicated experimental system, initially using monochromatic microscopic imaging and edge extraction algorithms to obtain the width information of the trenches. Subsequently, the trench depth was measured using the diffraction lattice light field generated by the micro-axicon array. Experimental results indicate that as the light field propagates from the top to the bottom of the trench, the light spots in the lattice light field shift in position due to the presence of diffraction angles, with the displacement being closely related to the trench depth. A mapping between the displacement and depth is established through geometric relationships, enabling the calculation of the trench depth. We tested nine trench samples with different aspect ratios, with the maximum aspect ratio reaching 58.12. The experimental results, compared with the scanning electron microscope measurement values, show that the measurement errors are all <9%.

Microsystems & NanoengineeringVol. 11(1)
Nankai University (CN)
Chinese Academy of Sciences, Tianjin University, Institute of Microelectronics of the Chinese Academy of Sciences
Affordable and clean energy
Openalex Percentile: Top 10%
Force Microscopy Techniques and Applications
2.49
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fast and accurate measurement of high aspect ratio MEMS trench array with optical lattice illumination — Dengfeng Kuang, Xu Li, et al. · Microsystems & Nanoengineering (2025) | TGRS Research Map | TGRS