Effect of Sprinkler Head Inclination on Water Flux Distribution

The installation inclination of a sprinkler head can affect the water flux distribution, thereby directly influencing the fire suppression performance . However, owing to the lack of specific regulations, in some cases, sprinkler heads are installed in a tilted position. In this study, we experimentally investigated the effects of sprinkler head inclination on water flux distribution. The inclination angles were set to 0°, 5°, 15°, and 25°, and the volume of water accumulated per unit area over a fixed period was measured at the floor level. A maximum measurement error of 5.24% was observed, which was within an acceptable range for data interpretation. The spray patterns and volume fraction distributions showed significant changes between 5° and 15° inclinations, resulting in notable nonuniformity in the water flux. Although the spray area showed minimal variation across the inclination angles, the degree of asymmetry in the spray area increased. Furthermore, as the inclination angle increased, the spray reach decreased in certain regions, with some areas falling short of the effective spray radius.

Authors

Publication Details

Journal
Fire Science and Engineering
Published
2025-08-28
DOI
https://doi.org/10.7731/kifse.a29b38ce
Primary Topic
Irrigation Practices and Water Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Sprinkler Head Inclination on Water Flux Distribution

Haeryong Heo, Taehoon Kim
Fire Science and Engineering
Irrigation Practices and Water Management
article

Effect of Sprinkler Head Inclination on Water Flux Distribution

Haeryong Heo, Taehoon Kim
article en

Abstract

The installation inclination of a sprinkler head can affect the water flux distribution, thereby directly influencing the fire suppression performance . However, owing to the lack of specific regulations, in some cases, sprinkler heads are installed in a tilted position. In this study, we experimentally investigated the effects of sprinkler head inclination on water flux distribution. The inclination angles were set to 0°, 5°, 15°, and 25°, and the volume of water accumulated per unit area over a fixed period was measured at the floor level. A maximum measurement error of 5.24% was observed, which was within an acceptable range for data interpretation. The spray patterns and volume fraction distributions showed significant changes between 5° and 15° inclinations, resulting in notable nonuniformity in the water flux. Although the spray area showed minimal variation across the inclination angles, the degree of asymmetry in the spray area increased. Furthermore, as the inclination angle increased, the spray reach decreased in certain regions, with some areas falling short of the effective spray radius.

Fire Science and EngineeringVol. 39(4)
Openalex Percentile: Top 71%
Irrigation Practices and Water Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.