Calibration and performance evaluation of PM <sub>2.5</sub> and NO <sub>2</sub> air quality sensors for environmental epidemiology

Abstract. Over the past few decades, the study and the use of air quality sensors have significantly increased, leading to a wealth of experience and a deeper understanding of their strengths and limitations. This study aimed to develop and evaluate a methodology for PM2.5 and NO2 sensors to enhance sensor accuracy to a level suitable for epidemiological studies, where ensuring data quality is paramount. The performance evaluation of indoor and outdoor sensors was carried out during the co-location phase with reference-equivalent instruments (RIs), by calculating the relative expanded uncertainties (REUs) stated in the EU Air Quality Directive 2008/50/EC and the recently published EU Directive 2024/2881, target diagrams and common error metrics, before the deployment of the air quality sensor systems (AQSSs) in the houses of patients suffering from chronic obstructive pulmonary disease (COPD) or asthma, in Stuttgart (Germany). Regression and machine learning (ML) models for sensor calibration were tested during the co-location. Moreover, an original methodology was designed and evaluated to validate the sensor data during the deployment in the houses of the participants. The study found that indoor sensor calibration using artificially generated NO2 and aerosols does not ensure model transferability, emphasizing the need for training data that matches the intended deployment environment in terms of real patterns of concentration, particle composition and environmental conditions. Moreover, the effect of the aggregation time (1, 5, 10, and 15 min) on the performance of the calibration models was evaluated for NO2 sensors. Integrating metadata such as activity logs, window status, and data from official monitoring stations, as well as NO2 measurements with diffusion tubes, proved to be helpful for data validation and interpretation during the sensor deployment in the houses of the participants.

Authors

Institutions

Publication Details

Journal
Atmospheric measurement techniques
Published
2025-08-28
DOI
https://doi.org/10.5194/amt-18-4061-2025
Citations
1
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.80

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibration and performance evaluation of PM 2.5 and NO 2 air quality sensors for environmental epidemiology

Miriam Chacón-Mateos, Héctor García-Salamero, Bernd Laquai, Ulrich Vogt
1 citations
Atmospheric measurement techniques
Air Quality Monitoring and Forecasting
0.80
article

Calibration and performance evaluation of PM 2.5 and NO 2 air quality sensors for environmental epidemiology

Miriam Chacón-Mateos, Héctor García-Salamero, Bernd Laquai, Ulrich Vogt
article en
1 citations

Abstract

Abstract. Over the past few decades, the study and the use of air quality sensors have significantly increased, leading to a wealth of experience and a deeper understanding of their strengths and limitations. This study aimed to develop and evaluate a methodology for PM2.5 and NO2 sensors to enhance sensor accuracy to a level suitable for epidemiological studies, where ensuring data quality is paramount. The performance evaluation of indoor and outdoor sensors was carried out during the co-location phase with reference-equivalent instruments (RIs), by calculating the relative expanded uncertainties (REUs) stated in the EU Air Quality Directive 2008/50/EC and the recently published EU Directive 2024/2881, target diagrams and common error metrics, before the deployment of the air quality sensor systems (AQSSs) in the houses of patients suffering from chronic obstructive pulmonary disease (COPD) or asthma, in Stuttgart (Germany). Regression and machine learning (ML) models for sensor calibration were tested during the co-location. Moreover, an original methodology was designed and evaluated to validate the sensor data during the deployment in the houses of the participants. The study found that indoor sensor calibration using artificially generated NO2 and aerosols does not ensure model transferability, emphasizing the need for training data that matches the intended deployment environment in terms of real patterns of concentration, particle composition and environmental conditions. Moreover, the effect of the aggregation time (1, 5, 10, and 15 min) on the performance of the calibration models was evaluated for NO2 sensors. Integrating metadata such as activity logs, window status, and data from official monitoring stations, as well as NO2 measurements with diffusion tubes, proved to be helpful for data validation and interpretation during the sensor deployment in the houses of the participants.

Atmospheric measurement techniquesVol. 18(16)
University of Stuttgart (DE), Deutsches Zentrum für Luft- und Raumfahrt e. V. (DLR) (DE)
Universität Stuttgart, Ministerium für Soziales und Integration Baden-Württemberg
Openalex Percentile: Top 25%
Air Quality Monitoring and Forecasting
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.