Enhanced-resolution chirped-pulse interferometry

Chirped-pulse interferometry (CPI) is a classical low-coherence interferometry technique with automatic dispersion cancellation and improved resolution over white-light interference. Previous work showed that CPI with linearly chirped Gaussian laser pulses achieves a $\sqrt{2}$ improvement in resolution over conventional white-light interferometry, but this is less than the factor of 2 improvement exhibited by a comparable quantum technique. In this work, we show how a particular class of nonlinearly chirped laser pulses can meet, and even exceed, the factor of 2 improvement in resolution. This enhanced-resolution CPI removes the resolution advantage of quantum interferometers in dispersion-cancelled interferometry.

Authors

Institutions

Publication Details

Journal
Physical review. A/Physical review, A
Published
2025-08-28
DOI
https://doi.org/10.1103/5vd5-srqg
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced-resolution chirped-pulse interferometry

Mark D Berube, K. J. Resch, Michael D. Mazurek
Physical review. A/Physical review, A
Spectroscopy Techniques in Biomedical and Chemical Research
article

Enhanced-resolution chirped-pulse interferometry

Mark D Berube, K. J. Resch, Michael D. Mazurek
article en

Abstract

Chirped-pulse interferometry (CPI) is a classical low-coherence interferometry technique with automatic dispersion cancellation and improved resolution over white-light interference. Previous work showed that CPI with linearly chirped Gaussian laser pulses achieves a $\sqrt{2}$ improvement in resolution over conventional white-light interferometry, but this is less than the factor of 2 improvement exhibited by a comparable quantum technique. In this work, we show how a particular class of nonlinearly chirped laser pulses can meet, and even exceed, the factor of 2 improvement in resolution. This enhanced-resolution CPI removes the resolution advantage of quantum interferometers in dispersion-cancelled interferometry.

Physical review. A/Physical review, AVol. 112(2)
National Institute of Standards and Technology (US), University of Waterloo (CA), University of Colorado Boulder (US), University of Colorado System (US), National Institute of Standards (EG)
Canada First Research Excellence Fund, Natural Sciences and Engineering Research Council of Canada
Openalex Percentile: Top 84%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.