Influence of Shear Waves on Transcranial Ultrasound Propagation in Cortical Brain Regions

Transcranial ultrasound applications require accurate simulations to predict intracranial acoustic pressure fields. The current gold standard typically consists of calculating a longitudinal ultrasound wave propagation using a fluid skull model, which is based on full head CT images for retrieving the skull's geometry and elastic constants. Although this approach has extensively been validated for deep brain targets and routinely used in transcranial ultrasound ablation procedures, its accuracy in shallow cortical regions remains unexplored. In this study, we explore the shear wave effects associated with transcranial focused ultrasound propagation, both numerically and experimentally. The intracranial acoustic pressure was measured at different incidence angles at the parietal and frontal regions in an ex vivo human skull. The fluid-like skull model was then compared to the solid model comprising both longitudinal and shear waves. The results consistently show a larger error and variability for both models when considering an oblique incidence, reaching a maximum of 170% mean deviation of the focal area when employing the fluid skull model. Statistical assessments further revealed that ignoring shear waves results in an average ∼40% overestimation of the intracranial acoustic pressure and inability to obtain an accurate intracranial acoustic pressure distribution. Moreover, the solid model has a more stable performance, even when small variations in the skull-transducer relative position are introduced. Our results could contribute to the refinement of the transcranial ultrasound propagation modeling methods thus help improving the safety and outcome of transcranial ultrasound therapy in the cortical brain areas.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Biomedical Engineering
Published
2025-08-28
DOI
https://doi.org/10.1109/tbme.2025.3603836
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Shear Waves on Transcranial Ultrasound Propagation in Cortical Brain Regions

Giovanni Colacicco, Béatrice Lauber, Beat Werner, Daniel Razansky et al.
1 links
IEEE Transactions on Biomedical Engineering
Ultrasound and Hyperthermia Applications
article

Influence of Shear Waves on Transcranial Ultrasound Propagation in Cortical Brain Regions

Giovanni Colacicco, Béatrice Lauber, Beat Werner, Daniel Razansky, Héctor Estrada, Yi‐Ming Chen, Ya Gao
article en

Abstract

Transcranial ultrasound applications require accurate simulations to predict intracranial acoustic pressure fields. The current gold standard typically consists of calculating a longitudinal ultrasound wave propagation using a fluid skull model, which is based on full head CT images for retrieving the skull's geometry and elastic constants. Although this approach has extensively been validated for deep brain targets and routinely used in transcranial ultrasound ablation procedures, its accuracy in shallow cortical regions remains unexplored. In this study, we explore the shear wave effects associated with transcranial focused ultrasound propagation, both numerically and experimentally. The intracranial acoustic pressure was measured at different incidence angles at the parietal and frontal regions in an ex vivo human skull. The fluid-like skull model was then compared to the solid model comprising both longitudinal and shear waves. The results consistently show a larger error and variability for both models when considering an oblique incidence, reaching a maximum of 170% mean deviation of the focal area when employing the fluid skull model. Statistical assessments further revealed that ignoring shear waves results in an average ∼40% overestimation of the intracranial acoustic pressure and inability to obtain an accurate intracranial acoustic pressure distribution. Moreover, the solid model has a more stable performance, even when small variations in the skull-transducer relative position are introduced. Our results could contribute to the refinement of the transcranial ultrasound propagation modeling methods thus help improving the safety and outcome of transcranial ultrasound therapy in the cortical brain areas.

IEEE Transactions on Biomedical EngineeringVol. 73(3)
University of Zurich (CH), ETH Zurich (CH), Institute for Biomedical Engineering (CH), University Children's Hospital Zurich (CH)
China Scholarship Council
Openalex Percentile: Top 79%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.