Passive Fault-Tolerant Scheme for Double-Phase Open-Circuit Fault in <i>n</i> × 3 Phase SPMSM With Connected Neutral Point

Aiming at the defects of traditional fault-tolerant control and fault detection systems, a diagnosis-free passive fault-tolerant control (PFTC) scheme for <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">n</i>×3-phase surface-mounted permanent magnet synchronous motors (SPMSM) with connected neutral point is proposed. To reduce the cost, volume, and complexity of the driver, this article adopts a mono-inverter parallel drive for <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">n</i>×3-phase motors, which is a prerequisite for achieving passive fault tolerance. By combining the <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">i<sub>d</sub></i>=0 control strategy and field-oriented control technology of the traditional three-phase PMSMs, the self-healing capability can be realized after <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">n</i>×3-phase SPMSMs experience double-phase open-circuit faults. Due to the proposed PFTC scheme not requiring the fault diagnosis process, the impact of misdiagnosis and diagnostic delays can be fundamentally avoided. In addition, there is no need to optimize the modulation strategy, motor model, or reference current before and after the fault, thus enabling smooth switching between different operating states. The proposed PFTC scheme can not only achieve seamless switching under multiple operating conditions but also be simple and easy to operate. The experimental results are carried out to verify the effectiveness and feasibility of the proposed method.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Emerging and Selected Topics in Power Electronics
Published
2025-08-28
DOI
https://doi.org/10.1109/jestpe.2025.3603919
Primary Topic
Cryptography and Data Security
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Passive Fault-Tolerant Scheme for Double-Phase Open-Circuit Fault in n × 3 Phase SPMSM With Connected Neutral Point

Meiling Zhao, Xuhui Zhu, Kailiang Yu, Kama Huang et al.
IEEE Journal of Emerging and Selected Topics in Power Electronics
Cryptography and Data Security
article

Passive Fault-Tolerant Scheme for Double-Phase Open-Circuit Fault in n × 3 Phase SPMSM With Connected Neutral Point

Meiling Zhao, Xuhui Zhu, Kailiang Yu, Kama Huang, Feng Yu, Christopher H. T. Lee
article en

Abstract

Aiming at the defects of traditional fault-tolerant control and fault detection systems, a diagnosis-free passive fault-tolerant control (PFTC) scheme for <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">n</i>×3-phase surface-mounted permanent magnet synchronous motors (SPMSM) with connected neutral point is proposed. To reduce the cost, volume, and complexity of the driver, this article adopts a mono-inverter parallel drive for <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">n</i>×3-phase motors, which is a prerequisite for achieving passive fault tolerance. By combining the <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">i<sub>d</sub></i>=0 control strategy and field-oriented control technology of the traditional three-phase PMSMs, the self-healing capability can be realized after <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">n</i>×3-phase SPMSMs experience double-phase open-circuit faults. Due to the proposed PFTC scheme not requiring the fault diagnosis process, the impact of misdiagnosis and diagnostic delays can be fundamentally avoided. In addition, there is no need to optimize the modulation strategy, motor model, or reference current before and after the fault, thus enabling smooth switching between different operating states. The proposed PFTC scheme can not only achieve seamless switching under multiple operating conditions but also be simple and easy to operate. The experimental results are carried out to verify the effectiveness and feasibility of the proposed method.

IEEE Journal of Emerging and Selected Topics in Power ElectronicsVol. 14(1)
Nanyang Technological University (SG), Nantong University (CN)
National Natural Science Foundation of China
Climate action
Openalex Percentile: Top 88%
Cryptography and Data Security
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.