Uncertainties in CO<sub>2</sub> Impurity Measurements Using FTIR

As carbon capture, utilization, and storage (CCUS) rapidly expands, reliable CO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> impurity monitoring is essential for verifying compliance with purity specifications. Although these specifications define which impurities must be controlled and at what levels, only a few CO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> purity requirements are typically determined on a project-by-project basis, and only a limited number are publicly available. Moreover, most specifications focus solely on specifying acceptable concentration limits, without guidance on how impurities should be measured and monitored. FTIR is a promising technique for online CO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> monitoring, but variations in calibration procedures can introduce significant uncertainty into the measurements. This study addresses the lack of calibration standardization in FTIR-based CO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> impurity monitoring by evaluating how operator-dependent selection of absorption regions affects the quantification of SO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> and CO. Seven operators independently calibrated the same FTIR system, each selecting their own absorption region based on their judgment and experience with spectral interpretation. This approach was used to assess the uncertainty introduced by operator-dependent calibration choices in the absence of standardized guidelines. The results show that these subjective decisions can lead to substantial variability in the predicted concentrations, exceeding 92.6% at low impurity levels, even though all models achieved detection limits well below the relevant specification thresholds. This highlights the risk of inconsistent impurity reporting in the absence of standardized procedures. In conclusion, this study not only demonstrates the magnitude of uncertainty introduced by operator-dependent FTIR calibration but also highlights the need for a standardized calibration procedure. By doing so, the study provides a practical approach to minimizing variability in impurity measurements and enhancing the reliability of compliance verification across CCUS projects.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-08-28
DOI
https://doi.org/10.1109/jsen.2025.3601622
Citations
1
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.76

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Uncertainties in CO2 Impurity Measurements Using FTIR

Dennis Severin Hansen, Khalil Kashefi, Kenneth René Simonsen, Simon Pedersen et al.
1 citations
IEEE Sensors Journal
Spectroscopy and Laser Applications
0.76
article

Uncertainties in CO2 Impurity Measurements Using FTIR

Dennis Severin Hansen, Khalil Kashefi, Kenneth René Simonsen, Simon Pedersen, K. H. Fornitz
article en
1 citations

Abstract

As carbon capture, utilization, and storage (CCUS) rapidly expands, reliable CO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> impurity monitoring is essential for verifying compliance with purity specifications. Although these specifications define which impurities must be controlled and at what levels, only a few CO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> purity requirements are typically determined on a project-by-project basis, and only a limited number are publicly available. Moreover, most specifications focus solely on specifying acceptable concentration limits, without guidance on how impurities should be measured and monitored. FTIR is a promising technique for online CO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> monitoring, but variations in calibration procedures can introduce significant uncertainty into the measurements. This study addresses the lack of calibration standardization in FTIR-based CO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> impurity monitoring by evaluating how operator-dependent selection of absorption regions affects the quantification of SO<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> and CO. Seven operators independently calibrated the same FTIR system, each selecting their own absorption region based on their judgment and experience with spectral interpretation. This approach was used to assess the uncertainty introduced by operator-dependent calibration choices in the absence of standardized guidelines. The results show that these subjective decisions can lead to substantial variability in the predicted concentrations, exceeding 92.6% at low impurity levels, even though all models achieved detection limits well below the relevant specification thresholds. This highlights the risk of inconsistent impurity reporting in the absence of standardized procedures. In conclusion, this study not only demonstrates the magnitude of uncertainty introduced by operator-dependent FTIR calibration but also highlights the need for a standardized calibration procedure. By doing so, the study provides a practical approach to minimizing variability in impurity measurements and enhancing the reliability of compliance verification across CCUS projects.

IEEE Sensors JournalVol. 25(19)
Hospital South West Jutland (DK), Aalborg University (DK)
Innovationsfonden
Openalex Percentile: Top 26%
Spectroscopy and Laser Applications
0.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.