Structural Behavior of Recycled Aggregate Concrete Continuous Beams

The structural behavior of continuous recycled aggregate concrete (RAC) beams under point loading at each span is examined experimentally in this work. Nine continuous beams, each 225 mm deep, 150 mm wide, and 3000 mm long, were tested as part of the program.As references, there were two beams made of normal concrete, one intended for shear failure and the other for flexural failure. Three beams were cast with different replacement ratios of recycled concrete Aggregate (20%, 40%, and 70%) to assess the effect of RAC content. The impact of RCA placement was also investigated using two flexure-critical beams and two shear-critical beams, each developed with a particular recycled aggregate location. The main experimental parameters included steel fiber, the position of recycled Aggregate, and the ratio of recycled aggregate replacement. According to the results, recycled Aggregate reduced the ultimate load by up to 5.38%. On the other hand, the ultimate load increased by as much as 10% when steel fiber was added. Additionally, flexural strength was reduced by up to 10% when recycled Aggregate was moved within beams intended for flexural failure. In contrast, shear-critical beams had a shear strength drop of up to 23% when the same modification was made.

Authors

Institutions

Publication Details

Journal
Journal of University of Babylon for Engineering Sciences
Published
2025-08-28
DOI
https://doi.org/10.29196/jubes.v33i4.5886
Primary Topic
Recycled Aggregate Concrete Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Structural Behavior of Recycled Aggregate Concrete Continuous Beams

Mohd Dawood, Lubna‏ ‏R. Alkhteeb
Journal of University of Babylon for Engineering Sciences
Recycled Aggregate Concrete Performance
article

Structural Behavior of Recycled Aggregate Concrete Continuous Beams

Mohd Dawood, Lubna‏ ‏R. Alkhteeb
article en

Abstract

The structural behavior of continuous recycled aggregate concrete (RAC) beams under point loading at each span is examined experimentally in this work. Nine continuous beams, each 225 mm deep, 150 mm wide, and 3000 mm long, were tested as part of the program.As references, there were two beams made of normal concrete, one intended for shear failure and the other for flexural failure. Three beams were cast with different replacement ratios of recycled concrete Aggregate (20%, 40%, and 70%) to assess the effect of RAC content. The impact of RCA placement was also investigated using two flexure-critical beams and two shear-critical beams, each developed with a particular recycled aggregate location. The main experimental parameters included steel fiber, the position of recycled Aggregate, and the ratio of recycled aggregate replacement. According to the results, recycled Aggregate reduced the ultimate load by up to 5.38%. On the other hand, the ultimate load increased by as much as 10% when steel fiber was added. Additionally, flexural strength was reduced by up to 10% when recycled Aggregate was moved within beams intended for flexural failure. In contrast, shear-critical beams had a shear strength drop of up to 23% when the same modification was made.

Journal of University of Babylon for Engineering SciencesVol. 33(4)
University of Babylon (IQ)
Openalex Percentile: Top 76%
Recycled Aggregate Concrete Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.