Integration of high-performance compact interferometric sensors in a suspended interferometer

Abstract Homodyne quadrature interferometers (HoQIs) are compact, low noise and high dynamic range displacement sensors designed for use in gravitational wave observatories. Their lower noise compared to the displacement sensors used at present makes them valuable for improving the seismic isolation in current and future detectors. This paper outlines the progression of this sensor from initial production and benchtop tests to in-vacuum static performance and installation in a gravitational wave detector prototype facility. A detailed design description is outlined, including the full signal and optical chain required for implementation in detectors. The measured in-vacuum static performance indicates a noise floor of 3– <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:mn>4</mml:mn> <mml:mo>×</mml:mo> <mml:msup> <mml:mn>10</mml:mn> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>13</mml:mn> </mml:mrow> </mml:msup> <mml:mstyle scriptlevel="0"/> <mml:mrow> <mml:mi mathvariant="normal">m</mml:mi> </mml:mrow> <mml:mstyle scriptlevel="0"/> <mml:msqrt> <mml:msup> <mml:mtext>Hz</mml:mtext> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>1</mml:mn> </mml:mrow> </mml:msup> </mml:msqrt> </mml:mrow> </mml:math> at 10 Hz. Three HoQIs were installed on the beamsplitter suspension at the Albert Einstein Institute 10 m gravitational wave detector prototype. They measured motion of the intermediate mass across the entire bandwidth measured and showed minimal non-linearities and a good robustness to motion in unmeasured degrees of freedom, both important for practical use in dynamic systems such as seismic isolation.

Authors

Institutions

Publication Details

Journal
Classical and Quantum Gravity
Published
2025-08-28
DOI
https://doi.org/10.1088/1361-6382/ae0087
Citations
2
Primary Topic
Advanced MEMS and NEMS Technologies
Type
article
Field-Weighted Citation Impact
1.46

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integration of high-performance compact interferometric sensors in a suspended interferometer

P Saffarieh, N. A. Holland, J. van Dongen, A. L. Mitchell et al.
2 citations
Classical and Quantum Gravity
Advanced MEMS and NEMS Technologies
1.46
article

Integration of high-performance compact interferometric sensors in a suspended interferometer

P Saffarieh, N. A. Holland, J. van Dongen, A. L. Mitchell, C. M. Mow‐Lowry, S. J. Cooper, Philip Koch, L. Prokhorov, J. Lehmann, M. Valentini
article en
2 citations

Abstract

Abstract Homodyne quadrature interferometers (HoQIs) are compact, low noise and high dynamic range displacement sensors designed for use in gravitational wave observatories. Their lower noise compared to the displacement sensors used at present makes them valuable for improving the seismic isolation in current and future detectors. This paper outlines the progression of this sensor from initial production and benchtop tests to in-vacuum static performance and installation in a gravitational wave detector prototype facility. A detailed design description is outlined, including the full signal and optical chain required for implementation in detectors. The measured in-vacuum static performance indicates a noise floor of 3– <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:mn>4</mml:mn> <mml:mo>×</mml:mo> <mml:msup> <mml:mn>10</mml:mn> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>13</mml:mn> </mml:mrow> </mml:msup> <mml:mstyle scriptlevel="0"/> <mml:mrow> <mml:mi mathvariant="normal">m</mml:mi> </mml:mrow> <mml:mstyle scriptlevel="0"/> <mml:msqrt> <mml:msup> <mml:mtext>Hz</mml:mtext> <mml:mrow> <mml:mo>−</mml:mo> <mml:mn>1</mml:mn> </mml:mrow> </mml:msup> </mml:msqrt> </mml:mrow> </mml:math> at 10 Hz. Three HoQIs were installed on the beamsplitter suspension at the Albert Einstein Institute 10 m gravitational wave detector prototype. They measured motion of the intermediate mass across the entire bandwidth measured and showed minimal non-linearities and a good robustness to motion in unmeasured degrees of freedom, both important for practical use in dynamic systems such as seismic isolation.

Classical and Quantum GravityVol. 42(19)
Leibniz University Hannover (DE), National Institute for Subatomic Physics (NL), Max Planck Institute for Gravitational Physics (DE), University of Birmingham (GB), Vrije Universiteit Amsterdam (NL)
International Max Planck Research School for Environmental, Cellular and Molecular Microbiology, European Commission, Deutsche Forschungsgemeinschaft, International Max Planck Research School for Advanced Methods in Process and Systems Engineering, Science and Technology Facilities Council, HORIZON EUROPE European Research Council
Openalex Percentile: Top 15%
Advanced MEMS and NEMS Technologies
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.