Enhanced Rotational Stability with the Locking Anchor EndoButton System: A Biomechanical Comparison of Free Bone Graft Non-Screw Methods for Anterior Shoulder Instability
All tested fixation methods provided sufficient stability under early postoperative loading conditions. However, the LAES demonstrated superior biomechanical performance, particularly in terms of rotational stability, compared to other non-screw fixation techniques.