A Modified Loss of Synchronism Condition for Efficient Critical Clearing Time (CCT) Estimation in Transient Stability Analysis

Accurate determination of critical clearing time (CCT) remains a fundamental challenge in transient stability analysis of power systems, primarily due to the highly nonlinear and complex dynamic behavior of multimachine networks. Existing methods based on the loss of synchronism (LOS) condition often require intensive numerical iterations and may suffer from convergence issues, particularly near the critical stability boundary. To address these limitations, this paper proposes a novel CCT estimation approach based on the critical trajectory method with a modified loss of synchronism (MLOS) condition. Unlike conventional LOS methods, the proposed MLOS approach linearizes the critical condition by assuming that the directional variation of the eigenvector associated with the zero eigenvalue of the Jacobian matrix is negligible, allowing it to be approximated as an identity matrix. This modification simplifies the critical trajectory formulation, significantly reduces the computational burden, and improves the numerical stability of the CCT determination process without sacrificing accuracy. Simulation results conducted on multiple benchmark test systems demonstrate that the proposed MLOS method achieves higher computational efficiency and comparable, if not superior, accuracy relative to traditional LOS‐based approaches. These results highlight the effectiveness and robustness of the MLOS method, making it a promising tool for accurate and efficient transient stability assessment in modern power systems.

Authors

Institutions

Publication Details

Journal
International Transactions on Electrical Energy Systems
Published
2025-01-01
DOI
https://doi.org/10.1155/etep/7526876
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Modified Loss of Synchronism Condition for Efficient Critical Clearing Time (CCT) Estimation in Transient Stability Analysis

Naoto Yorino, Ardyono Priyadi, Adi Soeprijanto, Ony Asrarul Qudsi
International Transactions on Electrical Energy Systems
Power System Optimization and Stability
article

A Modified Loss of Synchronism Condition for Efficient Critical Clearing Time (CCT) Estimation in Transient Stability Analysis

Naoto Yorino, Ardyono Priyadi, Adi Soeprijanto, Ony Asrarul Qudsi
article en

Abstract

Accurate determination of critical clearing time (CCT) remains a fundamental challenge in transient stability analysis of power systems, primarily due to the highly nonlinear and complex dynamic behavior of multimachine networks. Existing methods based on the loss of synchronism (LOS) condition often require intensive numerical iterations and may suffer from convergence issues, particularly near the critical stability boundary. To address these limitations, this paper proposes a novel CCT estimation approach based on the critical trajectory method with a modified loss of synchronism (MLOS) condition. Unlike conventional LOS methods, the proposed MLOS approach linearizes the critical condition by assuming that the directional variation of the eigenvector associated with the zero eigenvalue of the Jacobian matrix is negligible, allowing it to be approximated as an identity matrix. This modification simplifies the critical trajectory formulation, significantly reduces the computational burden, and improves the numerical stability of the CCT determination process without sacrificing accuracy. Simulation results conducted on multiple benchmark test systems demonstrate that the proposed MLOS method achieves higher computational efficiency and comparable, if not superior, accuracy relative to traditional LOS‐based approaches. These results highlight the effectiveness and robustness of the MLOS method, making it a promising tool for accurate and efficient transient stability assessment in modern power systems.

International Transactions on Electrical Energy SystemsVol. 2025(1)
Sepuluh Nopember Institute of Technology (ID), National Institute of Technology, Kure College (JP), Robotic Research (United States) (US)
Openalex Percentile: Top 78%
Power System Optimization and Stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Modified Loss of Synchronism Condition for Efficient Critical Clearing Time (CCT) Estimation in Transient Stability Analysis — Naoto Yorino, Ardyono Priyadi, et al. · International Transactions on Electrical Energy Systems (2025) | TGRS Research Map | TGRS