Resistance partial factor calibration for SFRC elements without shear reinforcement subjected to punching shear according to EN 1992-1-1:2023

Punching shear failure is often the governing design criterion of flat slabs at Ultimate Limit State and may potentially lead to progressive collapses. The latest version of Eurocode 2 (EN 1992–1–1:2023) introduces a new punching shear design model for fibre reinforced concrete (FRC) slabs in its Annex L. According to this approach, the concrete and shear reinforcement contributions are estimated based on the Critical Shear Crack Theory and the beneficial influence of the fibres is considered by means of the residual tensile strength of FRC. The model of EN 1992–1–1:2023 moves towards more rational approaches based on physical models. However, it appears that the reliability and applicability of the new formulation require further validation and calibration, particularly regarding the fibre contribution to the shear resistance. This paper is addressed at this topic, in an effort to provide a consistent safety format and calibrated values of the partial factors for the punching shear resistance of FRC. To that aim, an extensive literature review was conducted compiling a comprehensive database of steel fibre reinforced concrete (SFRC) slab-column connections without shear reinforcement. A total of 261 tests from 29 studies were collected. This database was subsequently filtered, considering only specimens with usual amounts of fibres and dimensions in construction, resulting into 67 representative tests. This database was later used to perform a probabilistic reliability-based calibration of the resistance partial factor associated with the fibre contribution γ V,FRC consistent with the FORM principles. The calibration considered different levels of scatter in the residual tensile strength of FRC, along with the target reliability index prescribed in the Eurocodes. The results show that a value of the resistance partial factor for the fibre contribution γ V,FRC equal to 1.30 may be adopted for expected scatters in the residual tensile strength of FRC up to 20 %, covering a wide range of practical applications. For higher levels of scatter, up to 30 % as a reasonable estimate of the maximum acceptable scatter in typical applications, a value γ V,FRC = 1.40 is suggested. For other cases, with even higher scatter or outside the range of parameters analysed, a detailed reliability analysis might be required. • Database of 261 tests compiled, subset of 67 used for reliability calibration of SFRC punching shear model in EN 1992-1-1:2023. • Study confirms EC2 safety format but proposes adjusted partial factors for fibres to align with target reliability levels. • Probabilistic calibration supports adjusted partial factors for fibres, based on SFRC variability, to meet reliability goals. • EN 1992-1-1:2023 punching shear model shows consistent accuracy and low variability versus experiments, confirming applicability.

Authors

Institutions

Publication Details

Journal
Engineering Structures
Published
2025-08-28
DOI
https://doi.org/10.1016/j.engstruct.2025.121219
Citations
1
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
1.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Resistance partial factor calibration for SFRC elements without shear reinforcement subjected to punching shear according to EN 1992-1-1:2023

Albert de la Fuente, Andrea Monserrat‐López, Miguel Fernández Ruiz, Jesús Miguel Bairán García
1 citations
Engineering Structures
Structural Behavior of Reinforced Concrete
1.01
article

Resistance partial factor calibration for SFRC elements without shear reinforcement subjected to punching shear according to EN 1992-1-1:2023

Albert de la Fuente, Andrea Monserrat‐López, Miguel Fernández Ruiz, Jesús Miguel Bairán García
article en
1 citations

Abstract

Punching shear failure is often the governing design criterion of flat slabs at Ultimate Limit State and may potentially lead to progressive collapses. The latest version of Eurocode 2 (EN 1992–1–1:2023) introduces a new punching shear design model for fibre reinforced concrete (FRC) slabs in its Annex L. According to this approach, the concrete and shear reinforcement contributions are estimated based on the Critical Shear Crack Theory and the beneficial influence of the fibres is considered by means of the residual tensile strength of FRC. The model of EN 1992–1–1:2023 moves towards more rational approaches based on physical models. However, it appears that the reliability and applicability of the new formulation require further validation and calibration, particularly regarding the fibre contribution to the shear resistance. This paper is addressed at this topic, in an effort to provide a consistent safety format and calibrated values of the partial factors for the punching shear resistance of FRC. To that aim, an extensive literature review was conducted compiling a comprehensive database of steel fibre reinforced concrete (SFRC) slab-column connections without shear reinforcement. A total of 261 tests from 29 studies were collected. This database was subsequently filtered, considering only specimens with usual amounts of fibres and dimensions in construction, resulting into 67 representative tests. This database was later used to perform a probabilistic reliability-based calibration of the resistance partial factor associated with the fibre contribution γ V,FRC consistent with the FORM principles. The calibration considered different levels of scatter in the residual tensile strength of FRC, along with the target reliability index prescribed in the Eurocodes. The results show that a value of the resistance partial factor for the fibre contribution γ V,FRC equal to 1.30 may be adopted for expected scatters in the residual tensile strength of FRC up to 20 %, covering a wide range of practical applications. For higher levels of scatter, up to 30 % as a reasonable estimate of the maximum acceptable scatter in typical applications, a value γ V,FRC = 1.40 is suggested. For other cases, with even higher scatter or outside the range of parameters analysed, a detailed reliability analysis might be required. • Database of 261 tests compiled, subset of 67 used for reliability calibration of SFRC punching shear model in EN 1992-1-1:2023. • Study confirms EC2 safety format but proposes adjusted partial factors for fibres to align with target reliability levels. • Probabilistic calibration supports adjusted partial factors for fibres, based on SFRC variability, to meet reliability goals. • EN 1992-1-1:2023 punching shear model shows consistent accuracy and low variability versus experiments, confirming applicability.

Engineering StructuresVol. 343
Universidad Politécnica de Madrid (ES), Universitat Politècnica de Catalunya (ES)
Ministerio de Ciencia, Innovación y Universidades, Universitat Politècnica de Catalunya, Agencia Estatal de Investigación
Climate action
Openalex Percentile: Top 21%
Structural Behavior of Reinforced Concrete
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.