Pushing the resolution limit of coherent diffractive imaging

Coherent diffractive imaging (CDI), with its lensless geometry and theoretically perfect transfer function, is considered as one of the most promising paradigms to achieve the Abbe resolution limit. However, recent advances on pushing the resolution limit in high-numerical-aperture (NA) CDIs has thus far been challenging. Here, we report a nearly 0.9NA CDI with an optimized imaging factor (k = 0.501), pushing the Abbe resolution diffraction limit for the first time in ultra-high-NA scenarios. Leveraging this the ultra-high NA and the Abbe-limit k-factor, we demonstrate a record-high imaging resolution of 0.57 λ for CDIs. Our approach builds upon a novel computational framework termed 'rigorous Fraunhofer diffraction' that eliminates the Ewald sphere effect in CDIs, particularly for high NAs. Our framework transforms the general challenge of high-NA, resolution-limited CDIs from relying on approximate and complicated geometric corrections to a solvable problem through rigorous model-based computation.

Authors

Institutions

Publication Details

Journal
Light Science & Applications
Published
2025-08-28
DOI
https://doi.org/10.1038/s41377-025-01963-2
Citations
2
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
3.77

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pushing the resolution limit of coherent diffractive imaging

Honggang Gu, Jiamin Liu, Jing Du, Shiyuan Liu et al.
2 citations
Light Science & Applications
Advanced X-ray Imaging Techniques
3.77
article

Pushing the resolution limit of coherent diffractive imaging

Honggang Gu, Jiamin Liu, Jing Du, Shiyuan Liu, Li Liu, Ming Gong, B. H. Zhuang
article en
2 citations

Abstract

Coherent diffractive imaging (CDI), with its lensless geometry and theoretically perfect transfer function, is considered as one of the most promising paradigms to achieve the Abbe resolution limit. However, recent advances on pushing the resolution limit in high-numerical-aperture (NA) CDIs has thus far been challenging. Here, we report a nearly 0.9NA CDI with an optimized imaging factor (k = 0.501), pushing the Abbe resolution diffraction limit for the first time in ultra-high-NA scenarios. Leveraging this the ultra-high NA and the Abbe-limit k-factor, we demonstrate a record-high imaging resolution of 0.57 λ for CDIs. Our approach builds upon a novel computational framework termed 'rigorous Fraunhofer diffraction' that eliminates the Ewald sphere effect in CDIs, particularly for high NAs. Our framework transforms the general challenge of high-NA, resolution-limited CDIs from relying on approximate and complicated geometric corrections to a solvable problem through rigorous model-based computation.

Light Science & ApplicationsVol. 14(1)
Guangdong University of Technology (CN), Wuhan National Laboratory for Optoelectronics (CN), Huazhong University of Science and Technology (CN)
National Natural Science Foundation of China, Basic and Applied Basic Research Foundation of Guangdong Province
Openalex Percentile: Top 6%
Advanced X-ray Imaging Techniques
3.77
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.