Fabrication of Electroless Nickel Coated X-ray Ellipsoidal Mirrors with Hybrid Metrology Method combining CGH and Contact Profilometer

Ellipsoidal mirrors are essential for high-performance X-ray focusing. A hybrid metrology method combining computer-generated hologram (CGH) interferometry and contact profilometry to enable accurate figure measurement and fabrication for ellipsoidal mirrors is proposed. Contact profilometry is used to extract errors that would otherwise be misinterpreted as alignment aberrations in CGH, and to inform the selection of appropriate alignment aberrations decoupling strategies. Using this method, we fabricated an ellipsoidal mirror with a final figure error below 20 nm RMS, while conventional CGH reported a result below 10 nm RMS. This approach improves measurement reliability and supports high-precision X-ray mirror manufacturing.

Authors

Publication Details

Journal
Optics Express
Published
2025-08-28
DOI
https://doi.org/10.1364/oe.574401
Primary Topic
Surface Roughness and Optical Measurements
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fabrication of Electroless Nickel Coated X-ray Ellipsoidal Mirrors with Hybrid Metrology Method combining CGH and Contact Profilometer

Kun Wang, Zhanshan Wang, Pengfeng Sheng, Qiushi Huang et al.
Optics Express
Surface Roughness and Optical Measurements
article

Fabrication of Electroless Nickel Coated X-ray Ellipsoidal Mirrors with Hybrid Metrology Method combining CGH and Contact Profilometer

Kun Wang, Zhanshan Wang, Pengfeng Sheng, Qiushi Huang, Jun Yu, Zhao Shi
article en

Abstract

Ellipsoidal mirrors are essential for high-performance X-ray focusing. A hybrid metrology method combining computer-generated hologram (CGH) interferometry and contact profilometry to enable accurate figure measurement and fabrication for ellipsoidal mirrors is proposed. Contact profilometry is used to extract errors that would otherwise be misinterpreted as alignment aberrations in CGH, and to inform the selection of appropriate alignment aberrations decoupling strategies. Using this method, we fabricated an ellipsoidal mirror with a final figure error below 20 nm RMS, while conventional CGH reported a result below 10 nm RMS. This approach improves measurement reliability and supports high-precision X-ray mirror manufacturing.

Optics ExpressVol. 33(20)
Openalex Percentile: Top 76%
Surface Roughness and Optical Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fabrication of Electroless Nickel Coated X-ray Ellipsoidal Mirrors with Hybrid Metrology Method combining CGH and Contact Profilometer — Kun Wang, Zhanshan Wang, et al. · Optics Express (2025) | TGRS Research Map | TGRS