Exploring foundation models for multi-class muscle segmentation in MR images of neuromuscular disorders: A comparative analysis of accuracy and uncertainty

SAM's fine-tuned encoder/decoder outperformed nnU-Net 3D in Moderate and Severe cases (DSC: 0.886 vs 0.883 and 0.857 vs 0.850) and was comparable in Early (DSC: 0.925). MedSAM did not show an advantage over SAM. Regarding UQ, SAM exhibited superior calibration in Moderate and Severe groups (ECE: 3.6% vs. 5.1% and 3.3% vs. 7.1%), CONCLUSIONS:: In conclusion, our findings demonstrate that fine-tuning SAM yields superior performance, considering both accuracy and UQ metrics, highlighting its enhanced reliability in challenging NMD imaging scenarios.

Authors

Institutions

Publication Details

Journal
Computer Methods and Programs in Biomedicine
Published
2025-08-28
DOI
https://doi.org/10.1016/j.cmpb.2025.109035
Citations
1
Primary Topic
Extracellular vesicles in disease
Type
article
Field-Weighted Citation Impact
0.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploring foundation models for multi-class muscle segmentation in MR images of neuromuscular disorders: A comparative analysis of accuracy and uncertainty

Giuseppe Baselli, Marco Moscatelli, Marina Grisoli, Domenico Aquino et al.
1 citations
Computer Methods and Programs in Biomedicine
Extracellular vesicles in disease
0.81
article

Exploring foundation models for multi-class muscle segmentation in MR images of neuromuscular disorders: A comparative analysis of accuracy and uncertainty

Giuseppe Baselli, Marco Moscatelli, Marina Grisoli, Domenico Aquino, Alessandro Brusaferri, Giovanna Rizzo, Alfonso Mastropietro, Nicola Casali
article en
1 citations

Abstract

SAM's fine-tuned encoder/decoder outperformed nnU-Net 3D in Moderate and Severe cases (DSC: 0.886 vs 0.883 and 0.857 vs 0.850) and was comparable in Early (DSC: 0.925). MedSAM did not show an advantage over SAM. Regarding UQ, SAM exhibited superior calibration in Moderate and Severe groups (ECE: 3.6% vs. 5.1% and 3.3% vs. 7.1%), CONCLUSIONS:: In conclusion, our findings demonstrate that fine-tuning SAM yields superior performance, considering both accuracy and UQ metrics, highlighting its enhanced reliability in challenging NMD imaging scenarios.

Computer Methods and Programs in BiomedicineVol. 272
Tecnologie Avanzate (Italy) (IT), Fondazione IRCCS Istituto Neurologico Carlo Besta (IT), Politecnico di Milano (IT)
Fondazione Cariplo, Regione Lombardia, Ministero dell'Università e della Ricerca
Openalex Percentile: Top 24%
Extracellular vesicles in disease
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.