Scleral Perforation following Transscleral Diode Laser Cycloablation:

Transscleral Diode laser cycloablation (DLCA) is one of the cycloablative procedures usually used for treating cases of refractory glaucoma. We report here a case of 80 years old man, who underwent transscleral diode laser cycloablation in his left painful blind eye. The main aim of this treatment was to lower down the intraocular pressure so that his pain could be relieved. On regular follow up visit, just two weeks after the procedure, he presented with scleral perforation on inferior 180 degrees of eye exactly where laser was applied. His intraocular pressure was 12mmHg. Patient had to undergo tectonic and conjunctival grafting on emergency basis to save the integrity of the globe and to avoid phthisis, pain and infection. His post op intraocular pressure (IOP) was 10mmHg with graft in place. This is a very rare complication and to the authors knowledge, this is first reported case of scleral perforation following transscleral diode laser cycloablation in Pakistan

Authors

Publication Details

Journal
Journal of Bahria University Medical and Dental College
Published
2025-04-01
DOI
https://doi.org/10.51985/jbumdc2025518
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Scleral Perforation following Transscleral Diode Laser Cycloablation:

Afshan Ali
Journal of Bahria University Medical and Dental College
Intraocular Surgery and Lenses
article

Scleral Perforation following Transscleral Diode Laser Cycloablation:

Afshan Ali
article en

Abstract

Transscleral Diode laser cycloablation (DLCA) is one of the cycloablative procedures usually used for treating cases of refractory glaucoma. We report here a case of 80 years old man, who underwent transscleral diode laser cycloablation in his left painful blind eye. The main aim of this treatment was to lower down the intraocular pressure so that his pain could be relieved. On regular follow up visit, just two weeks after the procedure, he presented with scleral perforation on inferior 180 degrees of eye exactly where laser was applied. His intraocular pressure was 12mmHg. Patient had to undergo tectonic and conjunctival grafting on emergency basis to save the integrity of the globe and to avoid phthisis, pain and infection. His post op intraocular pressure (IOP) was 10mmHg with graft in place. This is a very rare complication and to the authors knowledge, this is first reported case of scleral perforation following transscleral diode laser cycloablation in Pakistan

Journal of Bahria University Medical and Dental CollegeVol. 15(02)
Openalex Percentile: Top 66%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.