Determination of SCC Contributed by DFIG Under Asymmetrical Short Circuit Fault

For the past decades, practical calculation method of short circuit current (SCC) contributed by doubly fed induction generator (DFIG) under asymmetrical short circuit fault is deficient due to its control strategies and unlinear equipment. Asymmetrical SCC of DFIG is much more complicated and may be higher than that of a symmetrical fault in some situations. To address the problem, analytical derivations of SCC under asymmetrical faults are presented by establishing current equations between DFIG windings and converter controller or crowbar protection. Each frequency component could be directly extracted from time-domain expressions. Furthermore, clear mathematical models of asymmetrical peak and steady-state SCC used for practical calculation of power systems are proposed. Simulation results verify the effectiveness and robustness to different parameters and fault conditions of the proposed method. Finally, the influences of possible parameters on characteristics of asymmetrical SCC are summarized based on the proposed method.

Institutions

Publication Details

Journal
CSEE Journal of Power and Energy Systems
Published
2025-01-01
DOI
https://doi.org/10.17775/cseejpes.2022.05130
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of SCC Contributed by DFIG Under Asymmetrical Short Circuit Fault

CSEE Journal of Power and Energy Systems
Power Systems Fault Detection
article

Determination of SCC Contributed by DFIG Under Asymmetrical Short Circuit Fault

article en

Abstract

For the past decades, practical calculation method of short circuit current (SCC) contributed by doubly fed induction generator (DFIG) under asymmetrical short circuit fault is deficient due to its control strategies and unlinear equipment. Asymmetrical SCC of DFIG is much more complicated and may be higher than that of a symmetrical fault in some situations. To address the problem, analytical derivations of SCC under asymmetrical faults are presented by establishing current equations between DFIG windings and converter controller or crowbar protection. Each frequency component could be directly extracted from time-domain expressions. Furthermore, clear mathematical models of asymmetrical peak and steady-state SCC used for practical calculation of power systems are proposed. Simulation results verify the effectiveness and robustness to different parameters and fault conditions of the proposed method. Finally, the influences of possible parameters on characteristics of asymmetrical SCC are summarized based on the proposed method.

CSEE Journal of Power and Energy Systems
North China Electric Power University (CN), China Electric Power Research Institute
Climate action
Openalex Percentile: Top 73%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.