From Volume to Mass: Transforming Volatile Organic Compound Detection with Photoionization Detectors and Machine Learning
(1) Objective: Volatile organic compounds (VOCs) monitoring in industrial parks is crucial for environmental regulation and public health protection. However, current techniques face challenges related to cost and real-time performance. This study aims to develop a dynamic calibration framework for accurate real-time conversion of VOCs volume fractions (nmol mol<sup>-1</sup>) to mass concentrations (μg m<sup>-3</sup>) in industrial environments, addressing the limitations of conventional monitoring methods such as high costs and delayed response times. (2) Methods: By innovatively integrating photoionization detector (PID) with machine learning, we developed a robust conversion model utilizing PID signals, meteorological data, and a random forest's (RF) algorithm. The system's performance was rigorously evaluated against standard gas chromatography-flame ionization detectors (GC-FID) measurements. (3) Results: The proposed framework demonstrated superior performance, achieving a coefficient of determination (R<sup>2</sup>) of 0.81, root mean squared error (RMSE) of 48.23 μg m<sup>-3</sup>, symmetric mean absolute percentage error (SMAPE) of 62.47%, and a normalized RMSE (RMSE<sub>norm</sub>) of 2.07%, outperforming conventional methods. This framework not only achieved minute-level response times but also reduced costs to just 10% of those associated with GC-FID methods. Additionally, the model exhibited strong cross-site robustness with R<sup>2</sup> values ranging from 0.68 to 0.69, although its accuracy was somewhat reduced for high-concentration samples (>1500 μg m<sup>-3</sup>), where the mean absolute percentage error (MAPE) was 17.8%. The inclusion of SMAPE and RMSE<sub>norm</sub> provides a more nuanced understanding of the model's performance, particularly in the context of skewed or heteroscedastic data distributions, thereby offering a more comprehensive assessment of the framework's effectiveness. (4) Conclusions: The framework's innovative combination of PID's real-time capability and RF's nonlinear modeling achieves accurate mass concentration conversion (R<sup>2</sup> = 0.81) while maintaining a 95% faster response and 90% cost reduction compared to GC-FID systems. Compared with traditional single-coefficient PID calibration, this framework significantly improves accuracy and adaptability under dynamic industrial conditions. Future work will apply transfer learning to improve high-concentration detection for pollution tracing and environmental governance in industrial parks.
Authors
- Yusen Duan (ORCID: https://orcid.org/0000-0002-3750-9295)
- Xiang Che
- Yunfei Cai
Institutions
- Fudan University (CN)
- Zhejiang Environmental Monitoring Center (CN)
Publication Details
- Journal
- Sensors
- Published
- 2025-08-27
- DOI
- https://doi.org/10.3390/s25175314
- Primary Topic
- Advanced Chemical Sensor Technologies
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Fudan University
- Shanghai International Science and Technology
- National Key Research and Development Program of China