Analisis Penggunaan UPS di Ruang Operasi RSUD Siti Fatimah

The hospital operating room is one of the most crucial facilities in health services, so it requires a stable, reliable, and uninterrupted electricity supply to ensure patient safety and smooth medical procedures. The slightest electrical outage can pose a major risk, given that almost all vital medical equipment in the operating room relies on an electrical power supply. Therefore, the Uninterruptible Power Supply (UPS) system has an important role as a backup solution to ensure the continuity of electrical energy. This study aims to analyze the performance, capacity, and burden of UPS at Siti Fatimah Palembang Hospital using quantitative methods. Data was obtained through direct observation, interviews with technicians, technical documentation, and measurement of current and load power with standard-compliant measuring equipment. The focus of the analysis was directed at the Online Double Conversion type UPS with a capacity of 20 kVA which functions as the main supplier of backup electricity in the three operating rooms. The measurement results show that the total load reaches 8,855.5 VA or equivalent to 44.2% of the total capacity of the UPS. This load comes from 24 units of vital medical equipment, including operating lights, patient monitors, ventilators, anesthesia machines, and electrosurgical devices spread evenly across three operating rooms. With a power factor of 0.92 and a measurement current of 39.8 A, the performance of the UPS is quite efficient and safe to use. This shows that UPS capacity still has spare space to bear additional loads in the event of an increase in the number of medical equipment in the future. The conclusion of this study is that UPS at Siti Fatimah Palembang Hospital is able to work optimally in maintaining the stability of power supply, so that it can ensure the continuity of critical medical services in the operating room.

Authors

Institutions

Publication Details

Journal
Uranus Jurnal Ilmiah Teknik Elektro Sains dan Informatika
Published
2025-08-27
DOI
https://doi.org/10.61132/uranus.v3i3.1034
Primary Topic
Management and Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analisis Penggunaan UPS di Ruang Operasi RSUD Siti Fatimah

Yudi Irwansi, Emidiana Emidiana, Mgs. Chaikal Dzaki
Uranus Jurnal Ilmiah Teknik Elektro Sains dan Informatika
Management and Optimization Techniques
article

Analisis Penggunaan UPS di Ruang Operasi RSUD Siti Fatimah

Yudi Irwansi, Emidiana Emidiana, Mgs. Chaikal Dzaki
article en

Abstract

The hospital operating room is one of the most crucial facilities in health services, so it requires a stable, reliable, and uninterrupted electricity supply to ensure patient safety and smooth medical procedures. The slightest electrical outage can pose a major risk, given that almost all vital medical equipment in the operating room relies on an electrical power supply. Therefore, the Uninterruptible Power Supply (UPS) system has an important role as a backup solution to ensure the continuity of electrical energy. This study aims to analyze the performance, capacity, and burden of UPS at Siti Fatimah Palembang Hospital using quantitative methods. Data was obtained through direct observation, interviews with technicians, technical documentation, and measurement of current and load power with standard-compliant measuring equipment. The focus of the analysis was directed at the Online Double Conversion type UPS with a capacity of 20 kVA which functions as the main supplier of backup electricity in the three operating rooms. The measurement results show that the total load reaches 8,855.5 VA or equivalent to 44.2% of the total capacity of the UPS. This load comes from 24 units of vital medical equipment, including operating lights, patient monitors, ventilators, anesthesia machines, and electrosurgical devices spread evenly across three operating rooms. With a power factor of 0.92 and a measurement current of 39.8 A, the performance of the UPS is quite efficient and safe to use. This shows that UPS capacity still has spare space to bear additional loads in the event of an increase in the number of medical equipment in the future. The conclusion of this study is that UPS at Siti Fatimah Palembang Hospital is able to work optimally in maintaining the stability of power supply, so that it can ensure the continuity of critical medical services in the operating room.

Uranus Jurnal Ilmiah Teknik Elektro Sains dan InformatikaVol. 3(3)
Universitas Palembang (ID), Universitas PGRI Palembang
Openalex Percentile: Top 66%
Management and Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.