Improvement and Radiation-Resistance Study of an Optical Displacement Sensing System Based on a Position Sensitive Detector

We report a method of improving the precision and resolution of sensing systems based on position sensitive detectors (PSDs). In the method, we improved the precision and resolution by reducing the gain of the condition circuit and conducting spatial filtering on the measured spot position. To demonstrate the method, we experimentally built a PSD-based displacement sensing system. With the system, a precision of 0.3 μm and a resolution of 0.5 μm were obtained. The precision is two orders of magnitude better than that obtained with the use of a commercial condition circuit (SPC02, SiTek, Partille, Sweden) and without using any filter. Moreover, we tested the radiation-resistance performance of the system using a 60Co radiation source. The system kept the precision and resolution after exposure to radiation with a dose set to 100 krad. Our study is very useful to realize high-precision PSD-based sensing in space.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-08-27
DOI
https://doi.org/10.3390/app15179383
Primary Topic
Astronomical Observations and Instrumentation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improvement and Radiation-Resistance Study of an Optical Displacement Sensing System Based on a Position Sensitive Detector

Huiyuan Chen, Z. Yan, Kai Ding, Xiaojing Ren et al.
Applied Sciences
Astronomical Observations and Instrumentation
article

Improvement and Radiation-Resistance Study of an Optical Displacement Sensing System Based on a Position Sensitive Detector

Huiyuan Chen, Z. Yan, Kai Ding, Xiaojing Ren, Mengxi Yu, Aimin Xiao, Guoqiang Chen, Tuo Zheng
article en

Abstract

We report a method of improving the precision and resolution of sensing systems based on position sensitive detectors (PSDs). In the method, we improved the precision and resolution by reducing the gain of the condition circuit and conducting spatial filtering on the measured spot position. To demonstrate the method, we experimentally built a PSD-based displacement sensing system. With the system, a precision of 0.3 μm and a resolution of 0.5 μm were obtained. The precision is two orders of magnitude better than that obtained with the use of a commercial condition circuit (SPC02, SiTek, Partille, Sweden) and without using any filter. Moreover, we tested the radiation-resistance performance of the system using a 60Co radiation source. The system kept the precision and resolution after exposure to radiation with a dose set to 100 krad. Our study is very useful to realize high-precision PSD-based sensing in space.

Applied SciencesVol. 15(17)
North China Electric Power University (CN), Chinese Academy of Sciences (CN), Technology and Engineering Center for Space Utilization (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 76%
Astronomical Observations and Instrumentation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.