Extraction of Fetal ECG by Logarithmic Hyperbolic Secant Adaptive Algorithm in Alpha-Stable Noise

Direct fetal electrocardiogram (FECG) plays a crucial role in assessing fetal health and monitoring pregnancy conditions. Extracting high-quality FECG signals from maternal abdominal electrocardiogram (AECG) recordings remains a significant challenge due to the low amplitude of the FECG, its overlap with the maternal electrocardiogram (MECG), and the potential exposure to impulsive noise in the real world. Adaptive filtering (AF) is an essential method for FECG extraction, however, its performance tends to degrade in the presence of impulsive noise, such as instrument interference. To address this limitation, we propose a novel AF algorithm based on a nonlinear logarithmic hyperbolic secant (LHS) cost function. Alpha-stable distribution is adopted to model the realistic noises due to its high scalability. To further enhance extraction accuracy and optimize the preset parameters, we introduce a hyperbolic tangent-like transformation and develop the improved logarithmic hyperbolic secant adaptive filtering (ILHSAF) algorithm. The proposed approach leverages the approximate linear interval of the LHS function to maximize the preservation of original FECG information within the AECG. We use the synthetic dataset FECGSYN as well as two real datasets, Daisy and NI-FECG, to evaluate the performance and our methods outperform other existing AF algorithms. The ILHSAF algorithm exhibits commendable performance in R-peak detection and full-wave analysis on both real-world datasets, indicating its effective denoising capability and robustness in FECG extraction. This advancement establishes a foundation for long-term maternal and fetal monitoring using portable devices, as the proposed algorithms are capable of real-time operation.

Authors

Publication Details

Journal
IEEE Journal of Biomedical and Health Informatics
Published
2025-01-01
DOI
https://doi.org/10.1109/jbhi.2025.3602834
Citations
3
Primary Topic
Advanced Adaptive Filtering Techniques
Type
article
Field-Weighted Citation Impact
4.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Extraction of Fetal ECG by Logarithmic Hyperbolic Secant Adaptive Algorithm in Alpha-Stable Noise

D. S. Zhai, Jiacheng Zhang, Mengjia Wang, Bo Ni et al.
3 citations
IEEE Journal of Biomedical and Health Informatics
Advanced Adaptive Filtering Techniques
4.00
article

Extraction of Fetal ECG by Logarithmic Hyperbolic Secant Adaptive Algorithm in Alpha-Stable Noise

D. S. Zhai, Jiacheng Zhang, Mengjia Wang, Bo Ni, Tao Liu
article en
3 citations

Abstract

Direct fetal electrocardiogram (FECG) plays a crucial role in assessing fetal health and monitoring pregnancy conditions. Extracting high-quality FECG signals from maternal abdominal electrocardiogram (AECG) recordings remains a significant challenge due to the low amplitude of the FECG, its overlap with the maternal electrocardiogram (MECG), and the potential exposure to impulsive noise in the real world. Adaptive filtering (AF) is an essential method for FECG extraction, however, its performance tends to degrade in the presence of impulsive noise, such as instrument interference. To address this limitation, we propose a novel AF algorithm based on a nonlinear logarithmic hyperbolic secant (LHS) cost function. Alpha-stable distribution is adopted to model the realistic noises due to its high scalability. To further enhance extraction accuracy and optimize the preset parameters, we introduce a hyperbolic tangent-like transformation and develop the improved logarithmic hyperbolic secant adaptive filtering (ILHSAF) algorithm. The proposed approach leverages the approximate linear interval of the LHS function to maximize the preservation of original FECG information within the AECG. We use the synthetic dataset FECGSYN as well as two real datasets, Daisy and NI-FECG, to evaluate the performance and our methods outperform other existing AF algorithms. The ILHSAF algorithm exhibits commendable performance in R-peak detection and full-wave analysis on both real-world datasets, indicating its effective denoising capability and robustness in FECG extraction. This advancement establishes a foundation for long-term maternal and fetal monitoring using portable devices, as the proposed algorithms are capable of real-time operation.

IEEE Journal of Biomedical and Health InformaticsVol. PP
Openalex Percentile: Top 6%
Advanced Adaptive Filtering Techniques
4.00
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Extraction of Fetal ECG by Logarithmic Hyperbolic Secant Adaptive Algorithm in Alpha-Stable Noise — D. S. Zhai, Jiacheng Zhang, et al. · IEEE Journal of Biomedical and Health Informatics (2025) | TGRS Research Map | TGRS