STUDY OF THERMOGRAVIMETRIC ANALYSIS AND SOME THERMAL PROPERTIES OF A BINARY MIXTURE OF POLYESTER AND GLASS FIBRES

The research involves using Thermo Gravemetric analysis) TGA(for Poly ester Resin as a base material it is fortfified with fiber glass; With a different mixing ratio(6%, 8% ) and processed at different temperatures(,25 50,100,150c ) Polymeric compositions were compared before and after reinforcement.When comparing values of (Wt%)350 with IDT and CDT values, we found that these values were consistent with CDT and IDT values for all supported Poly ester composites and the highest percentage was for Poly ester with fiber glass (EP + GF).Treatment temperatures (25,50 ,100,150C) had no effect the values of IDT and CDT, where some values increased and some decreased by increasing the processing temperature.

Publication Details

Journal
MINAR International Journal of Applied Sciences and Technology
Published
2025-03-01
DOI
https://doi.org/10.47832/2717-8234.22.41
Primary Topic
Material Properties and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

STUDY OF THERMOGRAVIMETRIC ANALYSIS AND SOME THERMAL PROPERTIES OF A BINARY MIXTURE OF POLYESTER AND GLASS FIBRES

MINAR International Journal of Applied Sciences and Technology
Material Properties and Applications
article

STUDY OF THERMOGRAVIMETRIC ANALYSIS AND SOME THERMAL PROPERTIES OF A BINARY MIXTURE OF POLYESTER AND GLASS FIBRES

article en

Abstract

The research involves using Thermo Gravemetric analysis) TGA(for Poly ester Resin as a base material it is fortfified with fiber glass; With a different mixing ratio(6%, 8% ) and processed at different temperatures(,25 50,100,150c ) Polymeric compositions were compared before and after reinforcement.When comparing values of (Wt%)350 with IDT and CDT values, we found that these values were consistent with CDT and IDT values for all supported Poly ester composites and the highest percentage was for Poly ester with fiber glass (EP + GF).Treatment temperatures (25,50 ,100,150C) had no effect the values of IDT and CDT, where some values increased and some decreased by increasing the processing temperature.

MINAR International Journal of Applied Sciences and TechnologyVol. 07(01)
Openalex Percentile: Top 65%
Material Properties and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.