Nanosecond scintillator decay time measurement using a pulsed X-ray source

Traditional methods for measuring the decay time of scintillators typically rely on radioactive source excitation (e.g., 137Cs, 241Am). However, this approach faces three key challenges: (1) stochastic timing of radiation pulse emissions due to the Poisson nature of radioactive decay, complicating precise determination of temporal initiation points; (2) low photon emission rates from conventional sources, which limit the characterization of scintillator response dynamics under high-repetition-rate conditions; and (3) inherent radiation safety concerns associated with radioactive isotopes. A nanosecond pulsed X-ray source with high-repetition-rate capability (12.5 MHz, 4 ns FWHM pulse width) was developed. By implementing synchronized trigger electronics, precise control of event initiation timing was achieved, enabling precision measurements of scintillator fluorescence lifetimes. Experimental results shows that the system can rapidly and accurately measure decay times over 20 ns. Specifically, the fast decay components of LYSO: Ce and YAP: Ce scintillators were determined to be 42.3 ns and 27.8 ns, respectively, with deviations of less than 1.5% compared to literature values (42 ns, 28 ns). The results indicate that this newly developed pulsed X-ray source is an effective and efficient tool for accurate scintillator decay time measurement, providing significant improvements in scintillator testing.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-08-26
DOI
https://doi.org/10.1049/icp.2025.2642
Citations
1
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
1.88
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nanosecond scintillator decay time measurement using a pulsed X-ray source

Tong Su, Yongqing Yan, Ruili Zhang, Li Yun et al.
1 citations
IET conference proceedings.
Radiation Detection and Scintillator Technologies
1.88
article

Nanosecond scintillator decay time measurement using a pulsed X-ray source

Tong Su, Yongqing Yan, Ruili Zhang, Li Yun, Lizhi Sheng, Q.Q. Zhang, Yongan Liu
article en
1 citations

Abstract

Traditional methods for measuring the decay time of scintillators typically rely on radioactive source excitation (e.g., 137Cs, 241Am). However, this approach faces three key challenges: (1) stochastic timing of radiation pulse emissions due to the Poisson nature of radioactive decay, complicating precise determination of temporal initiation points; (2) low photon emission rates from conventional sources, which limit the characterization of scintillator response dynamics under high-repetition-rate conditions; and (3) inherent radiation safety concerns associated with radioactive isotopes. A nanosecond pulsed X-ray source with high-repetition-rate capability (12.5 MHz, 4 ns FWHM pulse width) was developed. By implementing synchronized trigger electronics, precise control of event initiation timing was achieved, enabling precision measurements of scintillator fluorescence lifetimes. Experimental results shows that the system can rapidly and accurately measure decay times over 20 ns. Specifically, the fast decay components of LYSO: Ce and YAP: Ce scintillators were determined to be 42.3 ns and 27.8 ns, respectively, with deviations of less than 1.5% compared to literature values (42 ns, 28 ns). The results indicate that this newly developed pulsed X-ray source is an effective and efficient tool for accurate scintillator decay time measurement, providing significant improvements in scintillator testing.

IET conference proceedings.Vol. 2025(17)
Xi'an Institute of Optics and Precision Mechanics (CN), University of Chinese Academy of Sciences (CN)
Affordable and clean energy
Openalex Percentile: Top 13%
Radiation Detection and Scintillator Technologies
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Nanosecond scintillator decay time measurement using a pulsed X-ray source — Tong Su, Yongqing Yan, et al. · IET conference proceedings. (2025) | TGRS Research Map | TGRS