Treatment of Aseptic Femur Non-union With Broken Intramedullary Nail In Situ by Exchange Nailing: A Technical Description

Non-union following intramedullary nailing of diaphyseal long bone fractures represents a serious complication necessitating timely and effective intervention. The situation becomes considerably more complex in the presence of a broken femoral nail, which poses additional technical challenges for the operating surgeon. Conventional management strategies typically entail removal of the existing nail, followed by re-fixation with a larger intramedullary nail, plate fixation, or external fixation constructs. Our case describes a 34-year-old male patient who presented with aseptic femur non-union complicated by refracture and hardware failure. The intramedullary nail had broken at two distinct sites as revealed by radiographs. A novel technique was employed to remove the broken hardware without surgically exposing the fracture site, followed by exchange nailing with a larger-diameter implant. A distal entry point in the femur was created in addition to the proximal entry site. After removal of the broken locking screws, a jig was attached proximally, and a solid reamer was introduced distally to engage the tip of the retained nail fragment. Simultaneous hammering was performed from both proximal and distal directions, enabling the extraction of all three nail fragments through the proximal entry point. The procedure was completed with the insertion of a wider intramedullary nail. The patient underwent successful fixation with exchange nailing, demonstrated progressive radiological healing, and ultimately achieved fracture union. At final follow-up, he had returned to full function without pain or restriction of daily activities. The described approach not only overcomes the challenges of implant removal but also raises awareness and shows a method to overcome its difficulty. This particular technique also reduces the risk of intraoperative and postoperative complications.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-08-26
DOI
https://doi.org/10.7759/cureus.91011
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Treatment of Aseptic Femur Non-union With Broken Intramedullary Nail In Situ by Exchange Nailing: A Technical Description

Salman Durrani, Nischay Kaushik, Shubham Agrawal, Jitender S. Saini et al.
Cureus
Bone fractures and treatments
article

Treatment of Aseptic Femur Non-union With Broken Intramedullary Nail In Situ by Exchange Nailing: A Technical Description

Salman Durrani, Nischay Kaushik, Shubham Agrawal, Jitender S. Saini, Juvesh Kumar, Pramod Kumar Sharma
article en

Abstract

Non-union following intramedullary nailing of diaphyseal long bone fractures represents a serious complication necessitating timely and effective intervention. The situation becomes considerably more complex in the presence of a broken femoral nail, which poses additional technical challenges for the operating surgeon. Conventional management strategies typically entail removal of the existing nail, followed by re-fixation with a larger intramedullary nail, plate fixation, or external fixation constructs. Our case describes a 34-year-old male patient who presented with aseptic femur non-union complicated by refracture and hardware failure. The intramedullary nail had broken at two distinct sites as revealed by radiographs. A novel technique was employed to remove the broken hardware without surgically exposing the fracture site, followed by exchange nailing with a larger-diameter implant. A distal entry point in the femur was created in addition to the proximal entry site. After removal of the broken locking screws, a jig was attached proximally, and a solid reamer was introduced distally to engage the tip of the retained nail fragment. Simultaneous hammering was performed from both proximal and distal directions, enabling the extraction of all three nail fragments through the proximal entry point. The procedure was completed with the insertion of a wider intramedullary nail. The patient underwent successful fixation with exchange nailing, demonstrated progressive radiological healing, and ultimately achieved fracture union. At final follow-up, he had returned to full function without pain or restriction of daily activities. The described approach not only overcomes the challenges of implant removal but also raises awareness and shows a method to overcome its difficulty. This particular technique also reduces the risk of intraoperative and postoperative complications.

CureusVol. 17(8)
Jawaharlal Nehru Medical College Hospital (IN), Ambedkar University Delhi (IN)
Openalex Percentile: Top 69%
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.