Sensitivity of effective dose to changes in tissue weighting factors

Effective dose E is the radiological protection quantity for stochastic health effects from whole-body exposure to ionising radiation. It is defined as a weighted sum of average absorbed doses in 15 selected tissues (organs), with weighting factors for radiation effectiveness and tissue sensitivity. This paper analyses the sensitivity of effective dose E with respect to the tissue weighting factors [Formula: see text]. It shows that a change of any single weighting factor by 100% results in relative changes of effective dose by a few percent for photons above an energy of 50 keV and for neutrons. Larger variations are observed for neutrons with an energy around 1 MeV and photons with low energies. The organs close to the body surface, breast and skin, are identified as the cause for these larger variations. Absolute changes of effective dose remain small, with exception for persons predominately exposed to low-energy photon radiation.

Authors

Institutions

Publication Details

Journal
Radiation and Environmental Biophysics
Published
2025-08-26
DOI
https://doi.org/10.1007/s00411-025-01143-1
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensitivity of effective dose to changes in tissue weighting factors

Thomas Otto
Radiation and Environmental Biophysics
Radiation Dose and Imaging
article

Sensitivity of effective dose to changes in tissue weighting factors

Thomas Otto
article en

Abstract

Effective dose E is the radiological protection quantity for stochastic health effects from whole-body exposure to ionising radiation. It is defined as a weighted sum of average absorbed doses in 15 selected tissues (organs), with weighting factors for radiation effectiveness and tissue sensitivity. This paper analyses the sensitivity of effective dose E with respect to the tissue weighting factors [Formula: see text]. It shows that a change of any single weighting factor by 100% results in relative changes of effective dose by a few percent for photons above an energy of 50 keV and for neutrons. Larger variations are observed for neutrons with an energy around 1 MeV and photons with low energies. The organs close to the body surface, breast and skin, are identified as the cause for these larger variations. Absolute changes of effective dose remain small, with exception for persons predominately exposed to low-energy photon radiation.

Radiation and Environmental BiophysicsVol. 64(4)
European Organization for Nuclear Research (CH)
CERN
Openalex Percentile: Top 69%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.