Damping of Low‐Frequency Oscillations in Grid‐Forming DFIG Employing the Swing Equation

ABSTRACT For a grid‐forming (GFM) doubly‐fed induction generator (DFIG) that employs a swing equation, low‐frequency oscillations may easily manifest, owing to the limited flexibility of tuning a swing equation for active damping. To address this issue, this article develops an active‐damping control for the GFM DFIG. The developed control is directly applied in parallel with the conventional swing equation, enabling a straightforward implementation in practice. Concerning the control tuning burden, the control development process restricts the number of control coefficients to just one. Subsequently, theoretical analyses are performed to validate the effectiveness of the proposed control method. Based on a practical DFIG integration system, the developed control has been further validated by the simulation studies in different scenarios.

Authors

Institutions

Publication Details

Journal
Electronics Letters
Published
2025-01-01
DOI
https://doi.org/10.1049/ell2.70394
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Damping of Low‐Frequency Oscillations in Grid‐Forming DFIG Employing the Swing Equation

Yajuan Guan, Juan C. Vásquez, Solomon Mamo Banteywalu, Yun Yu
Electronics Letters
Microgrid Control and Optimization
article

Damping of Low‐Frequency Oscillations in Grid‐Forming DFIG Employing the Swing Equation

Yajuan Guan, Juan C. Vásquez, Solomon Mamo Banteywalu, Yun Yu
article en

Abstract

ABSTRACT For a grid‐forming (GFM) doubly‐fed induction generator (DFIG) that employs a swing equation, low‐frequency oscillations may easily manifest, owing to the limited flexibility of tuning a swing equation for active damping. To address this issue, this article develops an active‐damping control for the GFM DFIG. The developed control is directly applied in parallel with the conventional swing equation, enabling a straightforward implementation in practice. Concerning the control tuning burden, the control development process restricts the number of control coefficients to just one. Subsequently, theoretical analyses are performed to validate the effectiveness of the proposed control method. Based on a practical DFIG integration system, the developed control has been further validated by the simulation studies in different scenarios.

Electronics LettersVol. 61(1)
Hawassa University (ET), Aalborg University (DK)
Danida Fellowship Centre
Openalex Percentile: Top 73%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Damping of Low‐Frequency Oscillations in Grid‐Forming DFIG Employing the Swing Equation — Yajuan Guan, Juan C. Vásquez, et al. · Electronics Letters (2025) | TGRS Research Map | TGRS