Alternating Magnetic Fields Remove Biofilms but Damage Cells on Implant Models Also with Negligible Bulk Heating

Implant-associated infections caused by bacterial biofilms remain a major clinical challenge, with high morbidity, often necessitating prolonged antibiotic therapy or implant revision surgery. To address the need for noninvasive alternatives, we investigated the use of alternating magnetic fields (AMFs) as a localized treatment modality for eradicating <i>Staphylococcus aureus</i> biofilms on titanium implant model surfaces. We demonstrate that AMF exposure effectively removes biofilms and kills bacteria at moderately elevated temperatures on the implant. Importantly, our results demonstrate that the antimicrobial efficacy of AMF treatment is primarily not due to heating. AMF vastly outperforms pure heating to the same temperatures for biofilm removal, despite inductive heating being the generally proposed mechanism for AMF antimicrobial action. Based on complementary imaging methods, we provide evidence that mechanical disruption, not a pure thermal effect, potentially driven by cavitation phenomena induced by transient, localized high temperature gradients, removes bacterial biofilms from titanium surfaces during AMF exposure. However, this mechanism also compromises the integrity of adjacent mammalian cells; confluent layers of SaOS-2 osteoblast-like cells exhibited actin cytoskeleton disintegration, membrane perforation, and a loss of viability even after brief AMF exposures. Our findings highlight a dual effect of AMF treatment: efficient biofilm removal is accompanied by collateral cytotoxicity, which requires further mechanistic research for clinically safe and effective AMF-based infection management strategies.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2025-08-26
DOI
https://doi.org/10.1021/acsami.5c12247
Primary Topic
Bacterial biofilms and quorum sensing
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Alternating Magnetic Fields Remove Biofilms but Damage Cells on Implant Models Also with Negligible Bulk Heating

Guruprakash Subbiahdoss, Erik Reimhult, Konstantin Nikolaus Beitl, Sandra Pérez-Jiménez
ACS Applied Materials & Interfaces
Bacterial biofilms and quorum sensing
article

Alternating Magnetic Fields Remove Biofilms but Damage Cells on Implant Models Also with Negligible Bulk Heating

Guruprakash Subbiahdoss, Erik Reimhult, Konstantin Nikolaus Beitl, Sandra Pérez-Jiménez
article en

Abstract

Implant-associated infections caused by bacterial biofilms remain a major clinical challenge, with high morbidity, often necessitating prolonged antibiotic therapy or implant revision surgery. To address the need for noninvasive alternatives, we investigated the use of alternating magnetic fields (AMFs) as a localized treatment modality for eradicating <i>Staphylococcus aureus</i> biofilms on titanium implant model surfaces. We demonstrate that AMF exposure effectively removes biofilms and kills bacteria at moderately elevated temperatures on the implant. Importantly, our results demonstrate that the antimicrobial efficacy of AMF treatment is primarily not due to heating. AMF vastly outperforms pure heating to the same temperatures for biofilm removal, despite inductive heating being the generally proposed mechanism for AMF antimicrobial action. Based on complementary imaging methods, we provide evidence that mechanical disruption, not a pure thermal effect, potentially driven by cavitation phenomena induced by transient, localized high temperature gradients, removes bacterial biofilms from titanium surfaces during AMF exposure. However, this mechanism also compromises the integrity of adjacent mammalian cells; confluent layers of SaOS-2 osteoblast-like cells exhibited actin cytoskeleton disintegration, membrane perforation, and a loss of viability even after brief AMF exposures. Our findings highlight a dual effect of AMF treatment: efficient biofilm removal is accompanied by collateral cytotoxicity, which requires further mechanistic research for clinically safe and effective AMF-based infection management strategies.

ACS Applied Materials & InterfacesVol. 17(36)
BioSurfaces (United States) (US)
Vienna Science and Technology Fund
Openalex Percentile: Top 80%
Bacterial biofilms and quorum sensing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Alternating Magnetic Fields Remove Biofilms but Damage Cells on Implant Models Also with Negligible Bulk Heating — Guruprakash Subbiahdoss, Erik Reimhult, et al. · ACS Applied Materials & Interfaces (2025) | TGRS Research Map | TGRS