Application of Patient Data–Based Quality Control in the Laboratory Serum Potassium and Magnesium Tests

Objective: The study aims to retrospectively analyze the results of serum potassium (K) and serum magnesium (Mg) tests conducted in the laboratory and evaluate the application of the patient data–based quality control (PDB‐QC) in the laboratory. Methods: All serum K and serum Mg testing data and quality control (QC) results from February 2022 to January 2023 were collected. After patient outliers were excluded and the data were sorted by test time, the data of the first half‐year period (from February 2022 to July 2022) constituted the training group, and the data of the second half‐year period (from August 2022 to January 2023) constituted the testing group. Average values and standard deviations (SDs) were calculated, and Z ‐score charts were plotted for PDB‐QC and internal quality control (IQC). The Sigma metrics (SMs) of K and Mg were calculated by using the Westgard online frequency calculator, and QC rules were determined according to the SM and the number of patient samples. The PDB‐QC and IQC were compared according to the determined QC rules. Results: The laboratory used the 2 2S and 1 3S rules to judge the systematic and random errors, respectively. PDB‐QC detected systematic errors 5 times and random errors 0 times for K, along with systematic errors 19 times and random errors 17 times for Mg. In comparison, IQC detected systematic errors 4 times and random errors 2 times for K, and systematic errors 1 time and random errors 2 times for Mg. Besides, PDB‐QC was faster than IQC in systematic and random error identification. Conclusion: Compared with IQC, PDB‐QC was capable of identifying more errors (except for random errors in K) with faster identification of both systematic and random errors for K and Mg. So, PDB‐QC is an effective means of monitoring the measurement status and improving laboratory quality management and can serve as an effective supplement to IQC.

Authors

Institutions

Publication Details

Journal
International Journal of Clinical Practice
Published
2025-01-01
DOI
https://doi.org/10.1155/ijcp/6345030
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of Patient Data–Based Quality Control in the Laboratory Serum Potassium and Magnesium Tests

Li-Rui Kong, Huali Wang, Yanqun Liu, Yan Zhang et al.
International Journal of Clinical Practice
Clinical Laboratory Practices and Quality Control
article

Application of Patient Data–Based Quality Control in the Laboratory Serum Potassium and Magnesium Tests

Li-Rui Kong, Huali Wang, Yanqun Liu, Yan Zhang, He Dahai, Chaoqiong Zhou, F. Wu, Shuang-Shuang Dai, Wenli Xu
article en

Abstract

Objective: The study aims to retrospectively analyze the results of serum potassium (K) and serum magnesium (Mg) tests conducted in the laboratory and evaluate the application of the patient data–based quality control (PDB‐QC) in the laboratory. Methods: All serum K and serum Mg testing data and quality control (QC) results from February 2022 to January 2023 were collected. After patient outliers were excluded and the data were sorted by test time, the data of the first half‐year period (from February 2022 to July 2022) constituted the training group, and the data of the second half‐year period (from August 2022 to January 2023) constituted the testing group. Average values and standard deviations (SDs) were calculated, and Z ‐score charts were plotted for PDB‐QC and internal quality control (IQC). The Sigma metrics (SMs) of K and Mg were calculated by using the Westgard online frequency calculator, and QC rules were determined according to the SM and the number of patient samples. The PDB‐QC and IQC were compared according to the determined QC rules. Results: The laboratory used the 2 2S and 1 3S rules to judge the systematic and random errors, respectively. PDB‐QC detected systematic errors 5 times and random errors 0 times for K, along with systematic errors 19 times and random errors 17 times for Mg. In comparison, IQC detected systematic errors 4 times and random errors 2 times for K, and systematic errors 1 time and random errors 2 times for Mg. Besides, PDB‐QC was faster than IQC in systematic and random error identification. Conclusion: Compared with IQC, PDB‐QC was capable of identifying more errors (except for random errors in K) with faster identification of both systematic and random errors for K and Mg. So, PDB‐QC is an effective means of monitoring the measurement status and improving laboratory quality management and can serve as an effective supplement to IQC.

International Journal of Clinical PracticeVol. 2025(1)
Chengdu University of Traditional Chinese Medicine (CN)
Chengdu University of Traditional Chinese Medicine, Chengdu University
Openalex Percentile: Top 72%
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.