Deep Learning for Cervical Spine Radiography: Automated Measurement of Intervertebral and Neural Foraminal Distances

<b>Background/Objectives:</b> The precise localization of cervical vertebrae in X-ray imaging was essential for effective diagnosis and treatment planning, particularly as the prevalence of cervical degenerative conditions increased with an aging population. Vertebrae from C2 to C7 were commonly affected by disorders such as ossification of the posterior longitudinal ligament (OPLL) and nerve compression caused by posterior osteophytes, necessitating thorough evaluation. However, manual annotation remained a major aspect of traditional clinical procedures, making it challenging to manage increasing patient volumes and large-scale medical imaging data. <b>Methods:</b> To address this issue, this study presented an automated approach for localizing cervical vertebrae and measuring neural foraminal distance. The proposed technique analyzed the neural foramen distance and intervertebral space using image enhancement to determine the degree of nerve compression. YOLOv8 was employed to detect and segment the cervical vertebrae. Moreover, by integrating automated cervical spine analysis with advanced imaging technologies, the system enabled rapid detection of abnormal intervertebral disc gaps, facilitating early identification of degenerative changes. <b>Results:</b> According to the results, the system achieved a spine localization accuracy of 99.5%, representing an 11.7% improvement over existing approaches. Notably, it outperformed previous methods by 66.67% in recognizing the C7 vertebra, achieving a perfect 100% accuracy. <b>Conclusions:</b> Furthermore, the system significantly streamlined the diagnostic workflow by processing each X-ray image in just 17.9 milliseconds. This approach markedly improved overall diagnostic efficiency.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2025-08-26
DOI
https://doi.org/10.3390/diagnostics15172162
Primary Topic
Medical Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep Learning for Cervical Spine Radiography: Automated Measurement of Intervertebral and Neural Foraminal Distances

Sze‐Teng Liong, Tsung‐Yi Chen, Patricia Angela R. Abu, Ya-Yun Huang et al.
Diagnostics
Medical Imaging and Analysis
article

Deep Learning for Cervical Spine Radiography: Automated Measurement of Intervertebral and Neural Foraminal Distances

Sze‐Teng Liong, Tsung‐Yi Chen, Patricia Angela R. Abu, Ya-Yun Huang, Tsun‐Kuang Chi, Kuo-Chen Li, Shu-Wei Tsai, Hongkai Wang, Wei‐Chen Tu, Chien-Feng Liu
article en

Abstract

<b>Background/Objectives:</b> The precise localization of cervical vertebrae in X-ray imaging was essential for effective diagnosis and treatment planning, particularly as the prevalence of cervical degenerative conditions increased with an aging population. Vertebrae from C2 to C7 were commonly affected by disorders such as ossification of the posterior longitudinal ligament (OPLL) and nerve compression caused by posterior osteophytes, necessitating thorough evaluation. However, manual annotation remained a major aspect of traditional clinical procedures, making it challenging to manage increasing patient volumes and large-scale medical imaging data. <b>Methods:</b> To address this issue, this study presented an automated approach for localizing cervical vertebrae and measuring neural foraminal distance. The proposed technique analyzed the neural foramen distance and intervertebral space using image enhancement to determine the degree of nerve compression. YOLOv8 was employed to detect and segment the cervical vertebrae. Moreover, by integrating automated cervical spine analysis with advanced imaging technologies, the system enabled rapid detection of abnormal intervertebral disc gaps, facilitating early identification of degenerative changes. <b>Results:</b> According to the results, the system achieved a spine localization accuracy of 99.5%, representing an 11.7% improvement over existing approaches. Notably, it outperformed previous methods by 66.67% in recognizing the C7 vertebra, achieving a perfect 100% accuracy. <b>Conclusions:</b> Furthermore, the system significantly streamlined the diagnostic workflow by processing each X-ray image in just 17.9 milliseconds. This approach markedly improved overall diagnostic efficiency.

DiagnosticsVol. 15(17)
Ming Chi University of Technology (TW), Chung Yuan Christian University (TW), Ateneo de Manila University (PH), Chang Gung Memorial Hospital (TW), Linkou Chang Gung Memorial Hospital (TW), Taiwan Semiconductor Manufacturing Company (Taiwan) (TW), Feng Chia University (TW), National Cheng Kung University (TW)
Ministry of Science and Technology, Taiwan, Feng Chia University, National Science and Technology Council
Openalex Percentile: Top 79%
Medical Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.