Bus Voltage Fluctuation Suppression Strategy for Hybrid Energy Storage Systems Based on MPC Power Allocation and Tracking
In view of the DC bus voltage fluctuation caused by the short-term periodic power demand of pulsed power loads (PPLs), this paper introduces a power allocation and tracking method for a hybrid energy storage system (HESS) with pulsed loads, aiming to improve the stability of the bus voltage. Firstly, a pulse power allocation and tracking method based on AC and DC components is proposed. Then, by introducing a current estimating method, a reference output current extraction from the AC component is obtained for model predictive control, which is used to control the supercapacitor converter, while the DC power is provided to inform the droop control to drive the battery converter. Finally, a frequency domain model is established to study the suppression effect of the control method on DC bus fluctuations, providing a reliable control scheme for HESS with pulsed power loads.
Authors
- Yuxiang Fu (ORCID: https://orcid.org/0000-0003-1351-5460)
- Yi Wei (ORCID: https://orcid.org/0000-0002-6624-9138)
- Z. B. Wang
- Liang Chen (ORCID: https://orcid.org/0009-0009-3500-1808)
- Yong Zhang (ORCID: https://orcid.org/0000-0003-0923-4498)
Publication Details
- Journal
- Electronics
- Published
- 2025-08-26
- DOI
- https://doi.org/10.3390/electronics14173390
- Primary Topic
- Microgrid Control and Optimization
- Type
- article
- Field-Weighted Citation Impact
- 0.00