Helical X-ray tube trajectory estimation via image noise analysis for enhanced CT dosimetry

Information on the helical trajectory of the X-ray tube is necessary for accurate dose evaluation during computed tomography (CT). We aimed to propose a methodology for analyzing the trajectory of the X-ray tube. The novelty of this paper is that the incident direction of X-rays is estimated from the standard deviation (SD) distribution. The X-ray incident direction for each slice was analyzed using a distribution function of SD values, in which the analysis regions were placed in the air region. Then, the helical trajectory of the CT scan was estimated by fitting a three-dimensional helical function to the analyzed data. The robustness of our algorithm was verified through phantom studies: the analyzed X-ray incident directions were compared with instrumental log data, in which cylindrical polyoxymethylene resin phantoms and a whole-body phantom were scanned. Chest CT scanning was mimicked, in which the field of view (FOV) was set at the lung region. The procedure for analyzing the X-ray incident direction was applicable to cylindrical phantoms regardless of the phantom size. In contrast, in the case of the whole-body phantom, although it was possible to apply our procedure to the chest and abdomen regions, the shoulder slices were inappropriate to analyze. Therefore, the helical trajectory was determined based on chest and abdominal CT images. The accuracy in X-ray incident direction analysis was evaluated to be 7.5°. In conclusion, we have developed an algorithm to estimate a three-dimensional helical trajectory that can be used for dose measurements and simulations. • A helical trajectory analysis procedure of an X-ray tube was proposed. • The X-ray incident direction can be determined from the image noise. • Each slice analysis can be extended to determine the helical trajectory. • Analysis of helical trajectory is necessary for dose measurement. • The impact on experimental and simulation studies was discussed.

Authors

Institutions

Publication Details

Journal
Radiation Physics and Chemistry
Published
2025-08-26
DOI
https://doi.org/10.1016/j.radphyschem.2025.113260
Citations
1
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
1.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Helical X-ray tube trajectory estimation via image noise analysis for enhanced CT dosimetry

Satoshi Morimoto, Hiroaki Hayashi, Kosaku Higashino, Natsumi Kimoto et al.
1 citations
Radiation Physics and Chemistry
Radiation Dose and Imaging
1.36
article

Helical X-ray tube trajectory estimation via image noise analysis for enhanced CT dosimetry

Satoshi Morimoto, Hiroaki Hayashi, Kosaku Higashino, Natsumi Kimoto, Rina Nishigami, Daiki Kobayashi, Motochika Maki, Takashi Asahara, Takegami Kazuki, Takeshi Konishi, Kazuta Yamashita, Tatsuya Maeda, Sota GOTO
article en
1 citations

Abstract

Information on the helical trajectory of the X-ray tube is necessary for accurate dose evaluation during computed tomography (CT). We aimed to propose a methodology for analyzing the trajectory of the X-ray tube. The novelty of this paper is that the incident direction of X-rays is estimated from the standard deviation (SD) distribution. The X-ray incident direction for each slice was analyzed using a distribution function of SD values, in which the analysis regions were placed in the air region. Then, the helical trajectory of the CT scan was estimated by fitting a three-dimensional helical function to the analyzed data. The robustness of our algorithm was verified through phantom studies: the analyzed X-ray incident directions were compared with instrumental log data, in which cylindrical polyoxymethylene resin phantoms and a whole-body phantom were scanned. Chest CT scanning was mimicked, in which the field of view (FOV) was set at the lung region. The procedure for analyzing the X-ray incident direction was applicable to cylindrical phantoms regardless of the phantom size. In contrast, in the case of the whole-body phantom, although it was possible to apply our procedure to the chest and abdomen regions, the shoulder slices were inappropriate to analyze. Therefore, the helical trajectory was determined based on chest and abdominal CT images. The accuracy in X-ray incident direction analysis was evaluated to be 7.5°. In conclusion, we have developed an algorithm to estimate a three-dimensional helical trajectory that can be used for dose measurements and simulations. • A helical trajectory analysis procedure of an X-ray tube was proposed. • The X-ray incident direction can be determined from the image noise. • Each slice analysis can be extended to determine the helical trajectory. • Analysis of helical trajectory is necessary for dose measurement. • The impact on experimental and simulation studies was discussed.

Radiation Physics and ChemistryVol. 239
Kanazawa University (JP), Kanazawa Medical University (JP), Kobe Tokiwa University (JP), Junshin Gakuen University (JP), Okayama University Hospital (JP), Yamaguchi University Hospital (JP), CTI Engineering (Japan) (JP), Shikoku Medical Center for Children and Adults (JP), Tokushima University (JP)
Affordable and clean energy
Openalex Percentile: Top 16%
Radiation Dose and Imaging
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.